FCP and SES Commands
8946121402
3-15
Send Diagnostic
A SES Application Client can use a
Send Diagnostic
command to configure/diagnose a
logical unit. After the command completion, the SES Application Client sends a
Receive
Diagnostic Results
command. See
. The
FCP_CDB
format is shown in
A Page Format (
PF
) bit of 1 specifies that the
Send Diagnostic
parameters conform to the
page structure as specified in SCSI-3 Primary Command (SPC), Revision 11a, X3T10/995D,
working draft. A value of 0 specifies that all parameters are vendor specific. At present, the
SESD only supports the vendor-specific page structures as defined in the
section.
The
selfTest
,
DevOfL
and
UnitOfL
bits are ignored by the SESD at present.
The Parameter List Length field specifies the length in bytes of the parameter list that shall be
transferred from the SES Application client to the SESD.
Test Unit Ready
An SES Application Client sends a
Test Unit Ready
command to check if the logical unit
is ready. The
FCP_CDB
format is shown in
The SESD returns the status of
GOOD
and
CHECK CONDITION
and a sense key of
NO SENSE
and an additional sense code of
NO ADDITIONAL SENSE INFORMATION
.
Table 3-26 Send Diagnostic Command Format
Byte/Bit
7
6
5
4
3
2
1
0
0
Operation Code = 1Dh
1
Reserved
PF
Reserved
selfTest
DevOfL
UnitOfL
2
Reserved
3 .. 4
Parameter list length
5
Control = 0
Table 3-27 Test Unit Ready Command Format
Byte/Bit
7
6
5
4
3
2
1
0
0
Operation Code = 00h
1 .. 4
Reserved
5
Control = 0
Summary of Contents for StorageNet 4000
Page 1: ...8946121402 StorageNet Fibre Channel Switch 4000 SES SCSI 3 Enclosure Services User Guide...
Page 2: ......
Page 3: ...8946121402 StorageNet Fibre Channel Switch 4000 SES SCSI 3 Enclosure Services User Guide...
Page 10: ...viii 8946121402...
Page 12: ...x 8946121402...
Page 16: ...SES Management 1 4 8946121402...
Page 20: ...Indicators and Control Management 2 4 8946121402...
Page 38: ...Introduction 4 2 8946121402...