StoneAge NA60IND Installation And Operation Instructions Manual Download Page 6

 

6

 

 

K.  Install  the  first  smaller  ring  of  the  upper  throat 
components, consisting of items 17, 18, 18C, 19, 20 
and 20C.  Ensure the ring is centered.  See Figure 
16. 

 

 

L.  Install  the  throat  cap  pieces,  items  21,  21C,  22 
and 22C, followed by the double flue adapter, item 
23B.  See Figures 17 and 18. 

 

 

 

M.  Install  Stone  Age  masonry  chimney  system, 
consisting of clay liners and outer blocks, or Stone 
Age Pipe Adapters if installing a metal pipe chim-
ney.  See Figures 19 and 20.  

 

13

14 

16 

15 

17

18 

19 

20 

21

22

23 Outer 

Block

22 

Clay Flue 

21

Figure 19. Stone Age Masonry Chimney 

Figure 15. Middle Throat Level 

Figure 16. Upper Throat Level 

Figure 17, Throat Cap 

18C 

20C 

14C 

16C 

21C 

22C 

Clay Flue 

23 Outer 

Block 

21C 

23B 

Figure 18, Double Flue Adapter 

23B 

Summary of Contents for NA60IND

Page 1: ...se instructions for future use 2 0 Description The fireplace is delivered as a kit with all compo nents necessary to complete the installation The kit is configured for a flue chimney but a special ad...

Page 2: ...2 Clearances See Figure 3 NA 60 Fireplace Item Clearance Figure 2 Refer ence Backwall 0 Sidewalls 0 to Appliances 18 from Fireplace open ing at points in front of fireplace Floor Non combustible exte...

Page 3: ...t important that the Stone Age fireplace be installed according to the following instructions It is also important that local building codes be consulted and followed Improper installation could resul...

Page 4: ...to back See Figure 4 C Install the bottom sidewalls 2 first followed by the bottom back plate pieces 3AL 3BL 3CL On the second level install the sidewalls 2 first then the back plates 3A 3B 3C so tha...

Page 5: ...t lip resting on the front header 8 Mortar damper in place Ensure the damper opens and closes properly I Install the first complete ring of four interlock ing throat components items 9 9C 10 11 11C an...

Page 6: ...Figures 17 and 18 M Install Stone Age masonry chimney system consisting of clay liners and outer blocks or Stone Age Pipe Adapters if installing a metal pipe chim ney See Figures 19 and 20 13 14 16 15...

Page 7: ...y system consisting of proprietary outer blocks and clay flues or metal pipe chimney pipe tested and certified to UL 103 standards for the US and ULC S604 standards for Canada 4 1 Stone Age Masonry Sy...

Page 8: ...of pitch J Use mortar to create a slope away from the clay flue running out to the edge of the finish material to assist with water drainage Install the chimney cap following instructions provided Thi...

Page 9: ...then be larger depending on the pitch of the roof See Figure 23 F Frame the opening ensuring that the recom mended minimum clearance to combustibles by the chimney pipe manufacturer exists between the...

Page 10: ...Never throw kick or by any other means force wood into the firebox as this could damage the firebrick and fireplace walls that could result in permanent damage and void the war ranty Stress cracks fro...

Page 11: ...ire at one time can result in over firing and too much heat in the firebox causing damage to the fireplace D When lighting a fire in a cold chimney a downdraft may be created letting a little smoke in...

Page 12: ...sure it is returned prior to laying the next fire D Keep the fireplace screen clean so air flows freely through it E Spot check the refractory bricks and mortar for small cracks It will expand slightl...

Page 13: ...13...

Page 14: ...turing defects in the Stone Age product and does not cover de fects or faulty workmanship in the installation of the product or the ma sonry or other structure in which it is installed Also this warra...

Reviews: