S
AT Command Reference
Release r02
www.stollmann.de
Page 17 of 33
All other values in the range of -127 to 127 could be set with this command as well,
but the equal or next lower value from the power table will be set internally.
Furthermore the value will be set to a value amongst minimum and maximum output
power value of the device.
Example:
AT+RFMAXTXPWR=0
The maximum output power will be set to 0 dBm
S
AT S Register
AT syntax:
ATSx=<value>
This command configures the S register settings.
Mode Description
Sx?
Show the current setting of register Sx
Sx=1
Set register Sx to 1
AT command S register set (all values in decimal format):
Register
Value
Description
S0
1
Immediate call acceptance
Note: Setting of S0only allow value 1 for BLE.. In case of BLE connections
always one RING is signalised and automatic call acceptance is set.
S2
43
Character for escape sequence
S3
13
Carriage-return character
S4
10
Line-feed character
S5
08
Backspace character
S12
100
Delay time by using the escape sequence in 10 ms increments
UICP
Set UART Interface Control Protocol
AT syntax:
AT+UICP=<mode>
This command sets the mode of the UART Interface Control Protocol (UICP).
To activate UICP, it is necessary to store the settings and perform a reset.
Mode Description
0
UICP off
1
UICP on
The valid sequence to e.g. activate UICP is: