Page 8
Due to continuous product research and development,
the information contained herein is subject to change without notice.
www.stoddart.com.au
www.stoddart.co.nz
3.1.1 W.HFHSQ23
3.1.2 W.HFHSQ24
Single Phase Units:
• Supplied and fi tted with an appropriately rated plug and lead, indicated as:
- 10A plug & lead fi tted
- 15A plug & lead fi tted
This unit must be installed in accordance with AS/NZS 60335.1
Some procedures in this manual require the power to the equipment to be turned off and
isolated. Turn the power OFF at the power point and unplug the power supply lead by the plug
body. If the power point is not readily accessible turn the equipment off at the isolation switch
or the circuit breaker in the switchboard. Attach a yellow “CAUTION-DO NOT OPERATE” tag.
This must be performed where relevant unless the procedures specify otherwise.
FAILURE TO DO SO MAY RESULT IN ELECTRIC SHOCK.
WARNING
Notes:
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a
hazard. Please contact Stoddart for parts and we will advise how to do this in order to avoid any electrical hazard
• The power cable should be dry and/or isolated from moisture or water
Specifications:
Model
W.HFHSQ.23
Height
696mm
Width
1120mm
Depth
757mm
Power
240VAC / 50Hz / 2.1kW
10A Plug & lead fitted
Specifications:
Model
W.HFHSQ.24
Height
696mm
Width
1460mm
Depth
757mm
Power
240VAC / 50Hz / 3.6kW
15A Plug & lead fitted
696
26
1120
297
460
757
750
696
26
1460
297
460
750
757
3.0 Specification
3.1 Technical Specifications