background image

Page 13

Due to continuous product research and development,

the information contained herein is subject to change without notice.

www.stoddart.com.au

www.stoddart.co.nz

Troubleshooting

(O) = Operator
(T) = Technician Task

Problem

Possible Causes

Task

Remedy

Unit does not operate / start

The mains isolating switch on the wall, circuit 

breaker or fuses are OFF at the power board

O

Turn isolating switch, circuit breaker or fuses 

ON

The power switch of the unit is OFF

O

Turn the power switch ON

Electrical wiring damaged

T

Replace / Fix electrical wiring

Unit not heating 

Temperature not set to the right setting

O

Check setting and adjust the temperature

Electronic Controller broken

T

Replace controller

Temperature probe broke

T

Replace probe

Element/s blown

T

Replace element/s

Food not at desired 

temperature

Thermostat set incorrectly

O

Adjust thermostat

Unit is not reaching required temperature

O/T

See above

Unable to adjust temperature

Element / thermostat failure

T

Test and replace the element or thermostat if 

necessary

WARNING

Technician tasks are only to be completed by qualified service 

people. Check faults before calling service technician.

•  If any faults/issues occur with the unit, follow the below troubleshooting procedures 
•  If the troubleshooting procedures do not correct the problem, contact the Stoddart Service Department

Cleaning and Maintenance

Disposal

If the appliance is no longer of use, please dispose in an environmentally correct way�

The distributor / retailer can contact their local metal recycling centre to collect the remaining cabinet, shelves, etc�

There may be special requirements or conditions�  Information on the disposal of refrigeration appliances can be obtained from:

•  Your supplier
•  Government authorities (The local council, Ministry of the Environment, etc�) 

Discarded electric appliances are recyclable and should not be discarded in the domestic waste! Please actively support us in 
conserving resources and protecting the environment by returning this appliance to the collection centres (if available)�

Dispose of packaging in accordance to applicable legal regulations�

 

Summary of Contents for Culinaire CH.WD

Page 1: ...he use care and maintenance of your quality Culinaire product Models CH WD 0111 CH WD 0211 WARMING DRAWERS SPECIFICATION INSTALLATION AND OPERATION MANUAL READ ALL INSTRUCTIONS BEFORE USE Revision 02...

Page 2: ...Page Intentionally Left Blank Page 1 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Page 3: ...ing Electrical Connection 6 Specification Technical Specifications 7 Code Explanation CH WD 0111 CH WD 0211 Operation Initial Start up Operation 9 Warming Drawer Initial Start up Warming Drawer Operat...

Page 4: ...his product is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or in...

Page 5: ...bjects to activate controls If any fault is detected refer to troubleshooting The manufacturer declines any liability for damages to persons and or things due to an improper wrong and or unreasonable...

Page 6: ...is subject to change without notice www stoddart com au www stoddart co nz Code Explanation CH Culinaire Heated WD Warming Drawer 0111 1 x 1 1 GN pans 0211 2 x 1 1 GN pans CT Castor Trolley Warming Dr...

Page 7: ...apable of supporting its weight Do not position the unit in wet areas near heat and or steam sources near flammable substances Allow 50mm air gap at the rear of the unit WARNING Improper installation...

Page 8: ...lanation CH WD 0111 SPECIFICATIONS Model CH WD 0111 Width 618mm Depth 625mm Height 343mm Capacity 1 x 1 1 Gastronorm Pans Voltage 220 240V 50Hz Power kW 0 55W 10 A plug lead fitted Connection 1 Phase...

Page 9: ...ddart com au www stoddart co nz Specification CH WD 0211 SPECIFICATIONS Model CH WD 0211 Width 618mm Depth 625mm Height 550mm Capacity 2 x 1 1 Gastronorm Pans Voltage 220 240V 50Hz Power kW 1 12kW 10...

Page 10: ...other switch can operate if the POWER button is OFF Ensure that the power cord is stored out of the way and can not be damaged The heater pads can be switch ON or OFF and the temperature can be adjus...

Page 11: ...ked Food Storage Food Safety All Gastronorm pans are sold separately Ensure only 1 type of product is placed in each pan to prevent cross contamination If more pans are needed contact your distributor...

Page 12: ...rasive pads or cleaners for cleaning All metal surfaces should be checked while cleaning for damage scuffs or scrapes as these can lead to rust and further damage to the product Mild rust and or corro...

Page 13: ...until all soil has been removed 6 Using a clean sanitised cloth thoroughly wipe the stainless steel and metal parts dry Do NOT let water pool on the unit Check crevices and folds Cleaning Procedure Ex...

Page 14: ...mostat failure T Test and replace the element or thermostat if necessary WARNING Technician tasks are only to be completed by qualified service people Check faults before calling service technician If...

Page 15: ...Page 14 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Page 16: ...7694 New Zealand Sales Spare Parts Tel 0800 79 1954 Email sales stoddart co nz Email spares stoddart co nz Service Spare Parts Tel 0800 935 714 Email service stoddart co nz Email spares stoddart co nz...