Operation
• The temperature range of this unit is 2°C - 12°C. The recommended temperature setting is 2°C - 4°C
• Different modes require different temperatures
• The temperature probe only measures the temperature of the water/air, NOT the food temperature
Temperature Adjustment
KEY FUNCTIONS:
Enter the status of parameter setting
Switch between menu and parameter
Adjust menu and parameters
Adjust menu and parameters;
Press 10s to execute parameter one-key recovery
Exit from parameter setting status
Exit from one-key recovery status
Force to start defrost
User parameter setting
In the status of temperature measuring and controlling, press and hold the
Set
key for three seconds to enter user parameter setting
state, it displays menu
St
in the digital tube. At this time, press the
Set
key to display the corresponding parameter value and press
or to adjust the set temperature, press the
Set
key to return to menu item
St
.
Enter to the administrator menu setting
In the user menu setting, when it displays menu item
St
in the digital tube, press to switch to the menu item
Po
, press
Set
key to
display
00
, and press and to adjust it to 55, then press
Set
key again to return to menu item
Po
. At this time, press key to
display
rd
, indicating that it has entered to the administrator parameter setting status. If it doesn't adjust to 55, press
Set
key to return
to menu time
Po
, then press the key ,it will exit from user parameter setting status and return to the temperature measuring and
control status.
Administrator parameter setting
After enter to the administrator parameter setting, press and to select menu items (St, Po, rd ......) ;
After select the item, press
Set
key to enter to the current parameter setting, press and to adjust parameters and then press
Set
key to return to the menu item.
Exit from parameter setting
Under the status of parameter setting, press key or no key operation within 30s, or if
Po
is not set as
55
, press key when it
displays menu item
Po
(i.e. password input error), it will save the current parameter value and exit from parameter setting.
Manual defrost
In the status of temperature measuring and controlling, press for three seconds to force the open or close of
defrost (d1 is not 0, i.e. defrost is not forbidden).
Code
Reason
Control Output
Remark
E1
Sensor failure
Run/Stop control output in a proportional time
/
dF
Defrost
Without defrost relay: off cycle defrost
With defrost relay: output defrost
/
dr
Parameter recovery
The original parameters will be overwritten by
the selected parameters
Factory operation mode