Integrated Bus
ID 442289.06
84
Operation manual POSIDYN® SDS 5000
11
WE
KEEP
THINGS
MOVING
Before you can use the IGB-Motionbus, you will have to:
•
first activate the function on all inverters integrated in the IGB network
•
and then parameterize the IGB-Motionbus on each inverter.
Chapter 11.3.5 also gives you information on how to parameterize the exchange of the master position via the
IGB-Motionbus.
11.3.1
Activation of the IGB-Motionbus
Select the IGB-Motionbus function in the configuration assistant in step 6.
Proceed as shown below to activate the IGB-Motionbus:
11.3.2
Parameterization of the IGB-Motionbus
The IGB-Motionbus is parameterized in two steps:
•
Configure the IGB-Motionbus
•
Parameterize the process data
These steps have to be performed for every inverter. You can simplify this job by using the assistants
IGB-
Motionbus configuration
and
IGB-Motionbus process data mapping
which will lead you through the process
of parameterizing the entire IGB-Motionbus in a project.
How to activate the IGB-Motionbus
1. Open the configuration assistant in POSITool.
2. Configure your application as usual in steps 1 to 5.
3. In step 6, select the inverter family SDS 5000.
4. Activate the checkbox
IGB-Motionbus
.
5. Exit the configuration assistant with the
Weiter
button.
6. Parameterize your application as you normally would.
7. Repeat steps 1 to 6 for each inverter which is integrated on the IGB-Motionbus.
8. Parameterize the IGB-Motionbus (see chapter 11.3.2).
9. Transfer the application to the inverters and save it.
10. Turn the 24 V power of all inverters off and on again.
You have now activated the IGB-Motionbus.
Information
Remember that you can only transmit parameters with PDO capability via the IGB-Motionbus.
Parameters with PDO capability are marked in the parameter list with the PDO attribute.