6.2 During commissioning
As the operating conditions for gear units are very different, it
must be ensured for safe operation under maximum
operating conditions that the surface temperature of the gear
unit does not exceed the maximum permitted value. For this
purpose, take the following measurement with a standard
commercial temperature measurement device.
Determine the surface temperature at the gear unit/motor
transition where the terminal box position prevents ventilation
by the motor fan.
For gear units with a motor adapter or free drive shaft,
determine the surface temperature at the joining seam
between the gear unit flange on the input side and the
attachments.
The maximum surface temperature is reached after approx. 3
hours under full load and may not exceed the maximum value
of 90° C for the highest surrounding temperature. Stop the
drive immediately if the maximum value is exceeded and
contact STOBER Service.
7
Service
7.1 Inspection and maintenance
To ensure safe operation with regard to explosion protection,
carry out the following inspections and maintenance work at
the specified intervals:
Daily or according to dust accumulation
•
Remove dust deposits from the gear unit surface
(STOBER recommends removing dust deposits with a
thickness of 1 mm or more)
Every 500 operating hours, every 3 months at the latest
•
Visually check the shaft seal rings for leaks
•
Check operating noise for possible bearing damage
Every 5000 operating hours, every 5 years at the latest
•
Replace lubricant
•
Replace shaft seal rings
Every 10000 operating hours
•
Replace rolling bearing
Comply with the lubricant specification and amount that is
stated on the nameplate of the gear unit when changing the
lubricant. Do not mix lubricants with different specifications.
7.2 In the event of disruptions
Changes compared to normal operation indicate that the
function of the drive has been impaired. This includes:
•
Higher power consumption, temperatures or vibrations
•
Unusual noises or odors
•
Leaks on the gear unit
•
Monitoring devices responding
In this case, stop the drive as quickly as possible and contact
STOBER Service.
7.3 Contact
STOBER Service will be happy to help you:
•
If you have queries about the product
•
In the event of a fault
•
Carrying out maintenance work
•
If you need spare parts.
Have the serial number and the type designation of the gear
unit ready when you contact us. This can be found on the
nameplate of the gear unit.
For spare part orders, you will also need the item number of
the spare part in the relevant spare parts list.
Contact data Parent company Germany:
STÖBER ANTRIEBSTECHNIK GmbH & Co. KG
Kieselbronner Str. 12
75177 Pforzheim
Service H49 7231 582-3000
[email protected]
Contact data Subsidiary USA:
STOBER Drives Inc.
1781 Downing Drive
Maysville KY 41056
Service H1 606 563-6035
[email protected]
7.4 Disposal
This product contains recyclable materials. Observe local
applicable regulations for disposal.