background image

Operating manual

Explosion-protected right angle servo gear units KL/KS/PHK/PHKX/PHQK/PK/PKX

4

ID 443005_en.01

WE KEEP THINGS MOVING

01/2019

en

www.stober.com

6.2 During commissioning

As the operating conditions for gear units are very different, it 
must  be  ensured  for  safe  operation  under  maximum 
operating conditions that the surface temperature of the gear 
unit does not exceed the maximum permitted value. For this 
purpose,  take  the  following  measurement  with  a  standard 
commercial temperature measurement device.
Determine  the  surface  temperature  at  the  gear  unit/motor 
transition where the terminal box position prevents ventilation 
by the motor fan.
For  gear  units  with  a  motor  adapter  or  free  drive  shaft, 
determine  the  surface  temperature  at  the  joining  seam 
between  the  gear  unit  flange  on  the  input  side  and  the 
attachments.
The maximum surface temperature is reached after approx. 3 
hours under full load and may not exceed the maximum value 
of  90°  C  for  the  highest  surrounding  temperature.  Stop  the 
drive  immediately  if  the  maximum  value  is  exceeded  and 
contact STOBER Service.

7

Service

7.1 Inspection and maintenance

To ensure safe operation with regard to explosion protection, 
carry out the following inspections and maintenance work at 
the specified intervals:

Daily or according to dust accumulation

Remove  dust  deposits  from  the  gear  unit  surface 
(STOBER  recommends  removing  dust  deposits  with  a 
thickness of 1 mm or more)

Every 500 operating hours, every 3 months at the latest

Visually check the shaft seal rings for leaks

Check operating noise for possible bearing damage

Every 5000 operating hours, every 5 years at the latest

Replace lubricant

Replace shaft seal rings

Every 10000 operating hours

Replace rolling bearing

Comply  with  the  lubricant  specification  and  amount  that  is 
stated on the nameplate of the gear unit when changing the 
lubricant. Do not mix lubricants with different specifications.

7.2 In the event of disruptions

Changes  compared  to  normal  operation  indicate  that  the 
function of the drive has been impaired. This includes:

Higher power consumption, temperatures or vibrations

Unusual noises or odors

Leaks on the gear unit

Monitoring devices responding

In this case, stop the drive as quickly as possible and contact 
STOBER Service.

7.3 Contact

STOBER Service will be happy to help you:

If you have queries about the product

In the event of a fault

Carrying out maintenance work

If you need spare parts.

Have the serial number and the type designation of the gear 
unit  ready  when  you  contact  us.  This  can  be  found  on  the 
nameplate of the gear unit.
For spare part orders, you will also need the item number of 
the spare part in the relevant spare parts list.

Contact data Parent company Germany:
STÖBER ANTRIEBSTECHNIK GmbH & Co. KG
Kieselbronner Str. 12
75177 Pforzheim
Service H49 7231 582-3000
[email protected]

Contact data Subsidiary USA:
STOBER Drives Inc.
1781 Downing Drive
Maysville KY 41056
Service H1 606 563-6035
[email protected]

7.4 Disposal

This  product  contains  recyclable  materials.  Observe  local 
applicable regulations for disposal. 

Summary of Contents for PHKX

Page 1: ...ntended 2 Safety information WARNING Failure to comply with these operating instructions can cause ignition sources when using the gear unit in areas subject to explosion hazard and lead to explosions that can cause serious injuries or even death Comply with the instructions in these operating instructions Also follow the applicable national local and system specific requirements CAUTION Burns The...

Page 2: ...tity according to the nameplate before commissioning the drive 5 Mounting Inspect the delivery for any transport damage immediately after you receive it Notify the transport company of any damage immediately Do not operate damaged gear units geared motors Remove the packaging of the gear unit geared motor and dispose of it according to the applicable legal requirements on site Check the following ...

Page 3: ...gear unit onto the machine shaft Coat machine shaft with mounting grease Coat hollow shaft spiral groove and keyway with mounting grease Fit gear unit by means of central screw Do not use hammer NOTICE Rust on of the gear unit Never mount the gear unit without lubrication since it will rust on and cannot be removed for repairs Disassembly Press the gear unit off by means of the push off disk and m...

Page 4: ...500 operating hours every 3 months at the latest Visually check the shaft seal rings for leaks Check operating noise for possible bearing damage Every 5000 operating hours every 5 years at the latest Replace lubricant Replace shaft seal rings Every 10000 operating hours Replace rolling bearing Comply with the lubricant specification and amount that is stated on the nameplate of the gear unit when ...