Installation
ID 442148.03
12
Commissioning Instructions CAN 5000 and DP 5000
3
WE KEEP THINGS MOVING
WARNING!
Danger of injury/death and property damage due to electric shock!
X
Before installing accessories, turn off all voltage supplies! Then wait 5 minutes for the DC link capacitors
to discharge. Never begin with accessory installation until after this!
NOTICE
Danger of property damage from incorrect installation of the devices!
X
It is essential to comply with the following installation instructions to avoid damage to the devices.
6
Guide the option board into the inverter so that the gold contacts slide into
the black connector:
7
Secure the metal plate to the inverter with the mounting screws:
Ö
You have now installed the accessory.