Electrical Supply

Installation must be carried out by a qualified electrician in 

accordance with BS 7671:2008 Wiring Regulations.

230/240V AC 50/60Hz mains supply to a suitable SELV 

LED Driver.

Ground recessed luminaire suitable for use in Zone 2 

applications as defined by BS EN 60598-2-13 table A1. 

Suitable for use in restricted accessible areas (e.g. 

pedestrians and pedal cycles only).

Site conditions: LED equipment is more susceptible to 

static damage and over voltage than previous technology. 

Before handling or connecting to the mains supply ensure 

that all MSL products are protected from static discharge 

and that the mains supply is to regulation. (230V +10 

-6%)

Mains cables must be double insulated, strain relieved 

and separated from E.L.V output cables.

This unit requires a constant current driver.  700mA Max.

 

Observe polarity:

Positive (+) is marked as RED.

Incorrect supply or reverse polarity can cause irreparable 

damage.

All connections must be made before switching on mains.  

If the supply is energised prior to making the connections 

to the fitting then the resulting surge will damage the LED.

All lighting equipment is delicate and easily damaged 

through misuse or inappropriate installation (mechanical 

or electrical). Repairs and replacements may cause 

delays and will be chargeable. Contact MSL for support if 

required.  For full warranty terms & conditions please visit 

our website.

The IP rating stated is applicable only when the fitting has 

been installed as per these instructions.

  

The light source contained in this luminaire shall only be 

replaced by the manufacturer or his service agent or a 

similar qualified person.

The entire dimming control circuit source must be of SELV 

insulation class.

Max exposed surface temperature 37°C at 25°C ambient

 

Installation

Check that the mounting surface is suitable for the 

installation of this fitting.  Max static load 5kN.

A 118mm diameter hole is required for mounting.

Step 1  Remove the fitting from the install sleeve by  

 

removing four M4 fixings in the front of the  

 

fitting.  Secure the installation sleeve so that  

 

it is flush with the pre cut hole and fill in any  

 

gap’s (Well drained ground is required.)

Step 2  Make mains connections to SELV LED driver  

 

and extra low voltage connections to the  

 fitting. 

Step 3  Push the fitting fully home into the mounting  

 

hole. Secure to the installation sleeve using  

 

the supplied screws.

Step 4  Use the supplied gloves to fit the magnetic  

 

coverplate onto the fitting.  Rotate clockwise  

 

until it clicks into position.

Ensure supply driver and connectors are housed 

indoors OR in a suitably IP rated enclosure.  Cable 

ends must be suitably waterproofed.  Inspect supply 

cables before installation to ensure there is no 

damage which will allow water to enter the fitting.  

After opening the sealed portion of the luminaire for 

any reason, MSL recommends running the fitting for 

15 minutes with the lid open to expel moisture before 

closing it up.  This will prevent condensation on the 

lens and protect the fitting from corrosion.

Care must be taken when handling any ingress 

protection seals, glands or "O" rings to ensure they 

are kept clean, unblemished and replaced exactly in 

their required location and suitably fastened home. 

WARNING: Do not look at exposed LED lamps in 

operation. Eye injury can result.

Cleaning:      

Fully isolate the fitting and allow to cool.

Clean the fitting with a slightly damp lint free cloth 

from a mild solution of soap and water.  The fitting 

must be completely dry before reconnecting power.

Incompatible or abrasive chemicals can damage the 

fitting, contact MSL for advice if required.

Badger M with Install Sleeve.pdf   2   20/08/2020   15:49:24