Electrical Supply
Installation must be carried out by a qualified electrician in
accordance with BS 7671:2008 Wiring Regulations.
230/240V AC 50/60Hz mains supply to a suitable SELV
LED Driver.
Ground recessed luminaire suitable for use in Zone 2
applications as defined by BS EN 60598-2-13 table A1.
Suitable for use in restricted accessible areas (e.g.
pedestrians and pedal cycles only).
Site conditions: LED equipment is more susceptible to
static damage and over voltage than previous technology.
Before handling or connecting to the mains supply ensure
that all MSL products are protected from static discharge
and that the mains supply is to regulation. (230V +10
-6%)
Mains cables must be double insulated, strain relieved
and separated from E.L.V output cables.
This unit requires a constant current driver. 700mA Max.
Observe polarity:
Positive (+) is marked as RED.
Incorrect supply or reverse polarity can cause irreparable
damage.
All connections must be made before switching on mains.
If the supply is energised prior to making the connections
to the fitting then the resulting surge will damage the LED.
All lighting equipment is delicate and easily damaged
through misuse or inappropriate installation (mechanical
or electrical). Repairs and replacements may cause
delays and will be chargeable. Contact MSL for support if
required. For full warranty terms & conditions please visit
our website.
The IP rating stated is applicable only when the fitting has
been installed as per these instructions.
The light source contained in this luminaire shall only be
replaced by the manufacturer or his service agent or a
similar qualified person.
The entire dimming control circuit source must be of SELV
insulation class.
Max exposed surface temperature 37°C at 25°C ambient
Installation
Check that the mounting surface is suitable for the
installation of this fitting. Max static load 5kN.
A 118mm diameter hole is required for mounting.
Step 1 Remove the fitting from the install sleeve by
removing four M4 fixings in the front of the
fitting. Secure the installation sleeve so that
it is flush with the pre cut hole and fill in any
gap’s (Well drained ground is required.)
Step 2 Make mains connections to SELV LED driver
and extra low voltage connections to the
fitting.
Step 3 Push the fitting fully home into the mounting
hole. Secure to the installation sleeve using
the supplied screws.
Step 4 Use the supplied gloves to fit the magnetic
coverplate onto the fitting. Rotate clockwise
until it clicks into position.
Ensure supply driver and connectors are housed
indoors OR in a suitably IP rated enclosure. Cable
ends must be suitably waterproofed. Inspect supply
cables before installation to ensure there is no
damage which will allow water to enter the fitting.
After opening the sealed portion of the luminaire for
any reason, MSL recommends running the fitting for
15 minutes with the lid open to expel moisture before
closing it up. This will prevent condensation on the
lens and protect the fitting from corrosion.
Care must be taken when handling any ingress
protection seals, glands or "O" rings to ensure they
are kept clean, unblemished and replaced exactly in
their required location and suitably fastened home.
WARNING: Do not look at exposed LED lamps in
operation. Eye injury can result.
Cleaning:
Fully isolate the fitting and allow to cool.
Clean the fitting with a slightly damp lint free cloth
from a mild solution of soap and water. The fitting
must be completely dry before reconnecting power.
Incompatible or abrasive chemicals can damage the
fitting, contact MSL for advice if required.
Badger M with Install Sleeve.pdf 2 20/08/2020 15:49:24