DocID018909 Rev 11
RM0090
Controller area network (bxCAN)
1112
CAN receive FIFO mailbox data length control and time stamp register
(CAN_RDTxR) (x=0..1)
Address offsets: 0x1B4, 0x1C4
Reset value: 0xXXXX XXXX
All RX registers are write protected.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
TIME[15:0]
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
FMI[7:0]
Reserved
DLC[3:0]
r
r
r
r
r
r
r
r
r
r
r
r
Bits 31:16
TIME[15:0]
:
Message time stamp
This field contains the 16-bit timer value captured at the SOF detection.
Bits 15:8
FMI[7:0]
:
Filter match index
This register contains the index of the filter the message stored in the mailbox passed
through. For more details on identifier filtering please refer to
Filter Match Index
paragraph.
Bits 7:4 Reserved, must be kept at reset value.
Bits 3:0
DLC[3:0]
:
Data length code
This field defines the number of data bytes a data frame contains (0 to 8). It is 0 in the case
of a remote frame request.