DocID025743 Rev 3
43/113
STM32F031x4 STM32F031x6
Electrical characteristics
86
6.3.2 Operating
conditions
at power-up / power-down
The parameters given in
are derived from tests performed under the ambient
temperature condition summarized in
6.3.3
Embedded reset and power control block characteristics
The parameters given in
are derived from tests performed under the ambient
temperature and supply voltage conditions summarized in
.
Table 19. Operating conditions at power-up / power-down
Symbol
Parameter
Conditions
Min
Max
Unit
t
VDD
V
DD
rise time rate
-
0
µs/V
V
DD
fall time rate
20
t
VDDA
V
DDA
rise time rate
-
0
V
DDA
fall time rate
20
Table 20. Embedded reset and power control block characteristics
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
V
POR/PDR
(1)
1.
The PDR detector monitors V
DD
and also V
DDA
(if kept enabled in the option bytes). The POR detector
monitors only V
DD
.
Power on/power down
reset threshold
Falling edge
(2)
2.
The product behavior is guaranteed by design down to the minimum V
POR/PDR
value.
1.80
1.88
1.96
(3)
3.
Data based on characterization results, not tested in production.
V
Rising edge
1.84
(3)
1.92
2.00
V
V
PDRhyst
PDR hysteresis
-
40
-
mV
t
RSTTEMPO
(4)
4.
Guaranteed by design, not tested in production.
Reset temporization
1.50
2.50
4.50
ms
Table 21. Programmable voltage detector characteristics
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
V
PVD0
PVD threshold 0
Rising edge
2.1
2.18
2.26
V
Falling edge
2
2.08
2.16
V
V
PVD1
PVD threshold 1
Rising edge
2.19
2.28
2.37
V
Falling edge
2.09
2.18
2.27
V
V
PVD2
PVD threshold 2
Rising edge
2.28
2.38
2.48
V
Falling edge
2.18
2.28
2.38
V
V
PVD3
PVD threshold 3
Rising edge
2.38
2.48
2.58
V
Falling edge
2.28
2.38
2.48
V