DocID024503 Rev 1
11/27
UM1631
Functional description
Figure 5. Full wave control description
Full wave pulse control is based on sending gate control pulse immediately after ZVC
signal. Gate control pulse length is defined by the software.
Refer to
for default gate current pulse duration for all AC switches. Duration of each
pulse is set separately for 50 Hz and 60 Hz mains.
$0
=9&
*DWHSXOVHOHQJWK
7ULDFJDWHVLJQDO
Table 2. Initial gate current pulse duration
Device
Variable name for 50 Hz mains
Initial gate
pulse
duration
(ms/timer
steps)
(1)
Variable name for 60 Hz mains
Initial gate
pulse
duration
(ms/timer
steps)
ACS1
ACS_1_SWITCHTIME_50HZ
10/100
ACS_1_SWITCHTIME_60HZ
8.3/83
ACS2
ACS_2_SWITCHTIME_50HZ
2/20
ACS_2_SWITCHTIME_60HZ
1.6/16
ACS3
ACS_3_SWITCHTIME_50HZ
2/20
ACS_3_SWITCHTIME_60HZ
1.6/16
Z0109
Z0109_SWITCHTIME_50HZ
2/20
Z0109_SWITCHTIME_60HZ
1.6/16
ACST16
ACST16_SWITCHTIME_50HZ
1/10
ACST16_SWITCHTIME_60HZ
0.8/8
T1635H
T1635H_SWITCHTIME_50HZ
1/10
T1635H_SWITCHTIME_60HZ
0.8/8
1. The timer step is 100 µs.