background image

Ⅰ  Panel Descriptions

 

FRONT PANEL

 

 

1. Gain Level Attenuator 

Establishes the required input level from -12dB to 0dB (0dB=0.775V). 

2. Output Level Indicator 

This level meter indicates the Amplifiers output level. 

3. Protect LED 

If protect conditions should occur, such as a excessively high operating temperatures with short in a output terminals cables or power on and off 
muting times, this LED will light and the amplifier will stop operation until the protect condition is corrected. 

4. Power Indicator LED (AC AND DC)

 

The VP240D/VP120D has two power indicators. Red LED is turn on by AC power and Green LED is turn on by DC input power. Either LED will 
light when the “ON” status of the unit. 

5. Power Switch

 

 

REAR PANEL 

400Hz

COM COLD HOT

COM

4ohm

8ohm

70V

100V

 

6. Power Receptacle and internal AC FUSE   

This is  a standard  3-prong  IEC  power  connector.  Connect  the  detachable  line  cord  (included in  the box)  to  the  power  receptacle,  and  plug  the 
other end of the line cord into an AC outlet. Standard IEC-type power cord connection. The internal AC Fuse is equipped with 10A 250V fast-blow 
fuse for AC input 110Vac to 120Vac countries. Other countries are 5A 250v Time-Lag FUSE for 220Vac-240Vac. 

7. DC Input Terminal and internal DC FUSE   

This  is  a  standard  5-way  binding  post connector.  Connect  the  +  24V  DC  Battery(100A  Type)  source  to  these  terminal.  Red(+)  connects  to 
battery's po), and Black(-) connects to battery's negative(-) side. The internal DC Fuse is equipped with 20A 35V Automotive type fuse for 
DC 24V input.   

8. Remote Power on/off Connector.

 

These connectors  are  for  external  remote  power  on  and  off.  The external  on/off  controls  will  be  effected  when the  main's  power  switch  is  off 
position.

 

9. High Pass Filter Switch.

 

This  400Hz  high  pass filter  activates for  reduce  internal  resonances  and  protect to speakers  from  damage caused  by  excessive  low  frequency 
transients.

 

10.Ground Lift Switch

 

This switch provides connection or disconnection between AC power "earth" ground and amplifier's ground to prevent ground loops noise. Under 
normal circumstances, this switch is set to "Frame" position. 

11.Audio Input Jacks (XLR Balanced) 

These jacks connect to pre-amplifier audio outputs or mixing console outputs. 

12.Link Connector (XLR and Screw Terminal)   

These jacks connect to added P.A amplifiers input jacks. 

13.Speaker Output Terminals 

The VP240D/VP120D is utilize five screw terminal for speaker connection. One terminal is common output terminals, two terminals are 4 ohm, 8 
ohm for conventional operating, and another two terminals are 70V,100V outputs for high impedance speaker operating. 

 

Make certain the combined impedance of the speakers is less than the rated impedance. 

Please refer to the specification page 10.

 

 

Summary of Contents for VP-120D

Page 1: ...VP 240D VP 120D Public Adress Power Amplifier OWNER S MANUAL ENGLISH...

Page 2: ...ality components such as an ultra low noise 5532 OP amplifiers and powerful 3 stage bi polar output devices with reliable quality power filter capacitors Amplifier s protection provided by short circu...

Page 3: ...te outlet Do not defeat the safety purpose of the polarized plug 9 Grounding If the appliance is equipped with a 3 wire grounding type plug a plug having a third grounding pin this plug will only fit...

Page 4: ...pro com STK LIMITED 1 YEAR WARRANTY STK electronics are warranted to be free from defects in materials and workmanship under normal use for a period of 1 year from date of original purchase During tha...

Page 5: ...ing post connector Connect the 24V DC Battery 100A Type source to these terminal Red connects to battery s positive and Black connects to battery s negative side The internal DC Fuse is equipped with...

Page 6: ...it and represents a dangerous safety hazard 3 Line Voltage Operate from AC mains not more than 5 above or below the specified line voltage Failure to comply may invalidate your warranty 4 Pre Connect...

Page 7: ...en connecting your speakers using each method be sure to pay close attention to proper polarity Although connecting your speaker systems out of phase using the wrong polarity will not damage your spea...

Page 8: ...status of various operating conditions Knowing what these indicator LEDs are telling you will help you to use your STK amplifier 1 Level Meter A level meter for main stage indicates that your signal l...

Page 9: ...9 Block Diagram...

Page 10: ...BALANCED Cooling 2 STEP FAN COOLING Dimension W x H x D Net 483 x 88 x 295 mm Shipping 400 x 550 x190 mm Weight Net 37 Ibs 16 8Kg Shipping 39 68 Ibs 18Kg Power Consumption 1 3 POWER 130Watts VP120D 2...

Page 11: ...11 Notes...

Page 12: ...12 Owner s Manual for The STK VP240D VP120D High Impedance Power Amplifier Printed In Korea APR 2010 STK Professional Audio VP240D VP120D...