Operating Manual:
CPF370L20
www.chinastirling.com
16
9
.
Input display
10
.
Number buttons
11
.
Continuously click 6 times at bottom left corner of screen to enter
factory setting interface
6. Factory setting interface operation instructions
The interface consists of 12 parts:
1. Back button, click to return to the previous interface;
2. Maximum power: set the maximum power required by the machine,
turn the power limit to "ON" to run the machine at the set power
3. Maximum rate: Machine boost rate setting. Turn on the rate limit to
"ON" to limit the machine boost rate.
4. Master control temperature: The machine contains 5 thermometers.
The temperature of T1 is used as the master control temperature.
5. Reporting interval: the time interval for reporting data to the server
6. Temperature compensation 1: T1 temperature compensation
7. Upper temperature limit: upper target temperature setting
8. Temperature compensation 4: T4 temperature compensation
9. Lower temperature limit: lower target temperature setting
10. Alarm temperature: the hot end temperature reaches this temperature
the alarm be ON and machine will stops.
11. Alarm current: When the machine is running, the AC current reaches
the set point the alarm be ON and machine will stops.
12. Hot-end threshold: limit the operating power of the machine when hot
forging reaches this temperature.