Stirling Black Edition STR-18R32WIFI Installation Manual Download Page 18

18

AFTER SALES SUPPORT

1300 886 649

[email protected]

AUS

MODEL: STR-18R32WIFI   PRODUCT CODE : 11894   10/2019

Installation (Cont.)

After having connected the pipe according to the instructions, install the 

connection cables, then the drain pipe (Fig. 14). After connection, lag the 

pipe, cables and drain pipe with the insulating material.
• Arrange the pipes, cables and drain hose well.
• Lag the pipe joints with insulating material, securing it with vinyl tape.
• Run the bound pipe, cables and drain pipe through the wall hole and mount 

the indoor unit onto the upper part of the mounting plate securely.

• Press and push the lower part of the indoor unit tightly against the 

mounting plate.

Summary of Contents for Black Edition STR-18R32WIFI

Page 1: ...erse Cycle Inverter Split System Air Conditioner with Wi Fi AFTER SALES SUPPORT 1300 886 649 info tempo org AUS MODEL STR 18R32WIFI PRODUCT CODE 11894 10 2019 INSTALLATION MANUAL Model Number STR 18R32WIFI ...

Page 2: ...ons on choosing to buy a STIRLING product All products brought to you by STIRLING are manufactured to the highest standards of performance and safety and as part of our philosophy of customer service and satisfaction are backed by our comprehensive warranty We hope you will enjoy using your purchase for many years to come ...

Page 3: ...UCT CODE 11894 10 2019 Contents 02 Welcome 04 Warranty Details 05 Installation Safety Instructions 10 Product Overview 13 Selecting the Installation Place 15 Installation 23 Information for the Installer 26 Other Useful Information 27 Repair and Refurbished Goods or Parts Notice ...

Page 4: ... in addition to all rights and remedies in respect of the product that the consumer has under the Competition and Consumer Act 2010 and similar state and territory laws Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and to compensation for any other reasonably foreseeable loss or damage You ar...

Page 5: ...ltage corresponds to that stamped on the rating plate Keep the switch or power plug clean Check and ensure that the socket is suitable for the plug The appliance must be fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category III conditions and these means must be incorporated in the fixed wiring ...

Page 6: ...thout continuously operating sources such as open flames an operating ignition gas appliance or an operating electric heater This air conditioner has been fully charged with refrigerant at the factory Should a recharge of refrigerant become necessary it may only be recharged by a professional installer Maintenance must only be carried out by properly qualified authorised personnel If the appliance...

Page 7: ... Where mmax is the allowable maximum charge in a room in kg M is the refrigerant charge amount in the appliance in kg Amin is the required minimum room area in m2 A is the room area in m2 LFL is the lower flammable limit in kg m3 h0 is the installation height of the appliance in metres for calculating mmax or Amin 1 8m for wall mounted Table 1 Maximum charge kg R32 LFL kg m3 h0 m Floor area m2 4 7...

Page 8: ... and maintenance The air inlets and outlets of both indoor and outdoor units should not be surrounded by obstacles or close to any hear source or combustible and or explosive environment The indoor unit inlet and outlets should be even Avoid areas where there are other electrical products power switch plugs and sockets kitchen cabinets beds sofas or other valuable items directly underneath the ind...

Page 9: ...able combustible refrigerant concentration detector which can realise two level audible and visual alarm its error must be not more than 10 C The concentration detectors should be calibrated regularly D It is necessary to check and confirm the functions before using the concentration detectors Pressure gauge The pressure gauges should be calibrated regularly a pressure gauge used for R410A can be ...

Page 10: ...y or similar room with high humidity levels The outdoor unit is installed outdoors on the ground or on a wall on suitable brackets NOTE Due to continued product improvement images and illustrations in this manual may vary slightly from the product purchased All images in this manual are for reference purposes only Parts are not necessarily pictured to scale 10 9 8 7 6 1 2 3 4 11 5 Scope of deliver...

Page 11: ...t Overview Cont B Outdoor unit parts No Part 12 Outdoor unit rating label 13 Terminal block cover 14 Air outlet grille 15 Gas valve 16 Liquid valve NOTE The diagrams throughout this manual are for illustrative purposes only and may vary slightly from the appearance of the unit purchased B 14 15 16 13 Fig 2 12 ...

Page 12: ...eries x2 Instruction and installation manuals Quick start guide Warranty certificate Fig 3 C 17 Installation hardware for illustrative purposes only not to scale 18 19 20 21 22 23 24 25 C Installation hardware No Part 17 Power cable 18 Copper nuts x4 19 Drainage pipe 20 Sealing colloid 21 Pipe insulation open tube 22 Binding tape 23 Rubber mats for outdoor unit x4 24 Screws plugs x8 25 Drainage mo...

Page 13: ...nditioner are for use by an appropriately qualified licensed installer The appliance must be installed in accordance with national wiring regulations Do not try to install the Air Conditioner on your own doing so will expose you to danger and void the warranty Do not install the unit where it will be exposed to direct sunlight Do not install the unit in a laundry room Install the unit where connec...

Page 14: ...neighbours Installation diagram Fig 6 Only persons and or companies qualified and experienced in the installation service and repair of refrigerant products should be permitted to do so The purchaser must ensure that the person and or company who is to install service or repair this air conditioner has qualifications and experience in refrigerant products Leave the minimum clearances around the un...

Page 15: ...ally Drill 32mm deep holes in the wall to fix the plate Use a drill bit to fit the 6mm plugs supplied Insert the plastic anchors into the hole Fix the mounting plate by using the provided tapping screws Fig 7 Check that the mounting plate is correctly fixed Drilling a hole in the wall for the piping Decide where to drill the hole in the wall for the piping if necessary according to the position of...

Page 16: ...ficient earth connection must be ensured The appliance must be fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category III conditions and these means must be incorporated in the fixed wiring in accordance with the wiring rules If the power cable is damaged contact the after sales support line for ...

Page 17: ...es working in opposite directions Fig 12 For R32 refrigerant mechanical connectors should be outdoors Water drainage from the indoor unit The condensed water drainage from the indoor unit is fundamental for the success of the installation Place the drain hose below the piping taking care not to create siphons The drain hose must slant down wards to aid drainage Fig 13 Do not bend the drain hose or...

Page 18: ...e Fig 14 After connection lag the pipe cables and drain pipe with the insulating material Arrange the pipes cables and drain hose well Lag the pipe joints with insulating material securing it with vinyl tape Run the bound pipe cables and drain pipe through the wall hole and mount the indoor unit onto the upper part of the mounting plate securely Press and push the lower part of the indoor unit tig...

Page 19: ...ration of the unit for many years to come without loosening The unit must be installed following all relevant local regulations Water drainage from the outdoor unit Condensed water and ice formed in the outdoor unit while in heating mode Fig 15 can be drained away through a drain pipe Fasten the drain port in the 25mm hole placed in the part of the unit as illustrated Fig 15 Connect the drain port...

Page 20: ...e some leakage With excessive tightening torque there may also be some leakage as the flange could be damaged The best way to tighten the connections is using a fixed wrench and a torque wrench as illustrated in Fig 12 on page 17 Bleeding Air and humidity left inside the refrigerant circuit can cause compressor malfunction After having connected the indoor and outdoor units bleed the air and humid...

Page 21: ...mp Open the 2 way valve by turn and then close it after 10 seconds Check all the joints for leaks using liquid soap or an electronic leak device Turn the body of the 2 way and 3 way valves Disconnect the vacuum pump hose Replace and tighten all the caps on the valves Fig 19 3 Way valve diagram Connect to indoor unit Open position Spindle Needle Service port cap Fig 20 Refrigerant flow direction 3 ...

Page 22: ...o that no air or water can enter Indoor unit test Does the ON OFF switch work properly Do the HEATING COOLING and FAN modes operate normally Do the TIMER ON and TIMER OFF functions operate properly Does each indicator light work properly Do the flaps for air flow direction operate normally Is the condensed water drained regularly Outdoor unit test Is there any abnormal noise or vibration during op...

Page 23: ...23 AFTER SALES SUPPORT 1300 886 649 info tempo org AUS MODEL STR 18R32WIFI PRODUCT CODE 11894 10 2019 Information for the Installer Wiring diagrams Indoor wiring diagram Outdoor wiring diagram ...

Page 24: ...between level 5m Model Capacity 5 1kW Power Supply Cable Sectional Area N min 1 5mm2 AWG16 L min 1 5mm2 AWG16 E min 1 5mm2 AWG16 Connection Supply Cable Sectional Area N min 1 5mm2 L min 1 5mm2 1 1 5mm2 2 1 5mm2 min 1 5mm2 Pipe details Cable wire specifications Tightening torque for protection caps and flange connection Pipe Diameter Tightening Torque N x m Corresponding Stress using a 20cm wrench...

Page 25: ... Power Input Cooling 1190W Heating 1180W Rated Power Input AS NZS 60335 Cooling 2300W Heating 2250W Room size suitability 30 35m2 Rated Voltage and Frequency 220 240V 50Hz Ingress Protection Outdoor Unit IPX4 Max Pressure Discharge 3 7MPa Suction 1 2MPa Noise SPL Indoor Unit 49dB A Outdoor Unit 59dB A Refrigerant Type Type R32 Quantity 1110g Indoor Airflow Volume Cooling 900m3 h Heating 930m3 h Ne...

Page 26: ...ntain substances that can have a detrimental effect on the environment and human health if disposed of inappropriately Observe any local regulations regarding the disposal of electrical consumer goods and dispose of it appropriately for recycling and recovery of the refrigerant Contact your local authorities for advice on recycling facilities in your area Licensed installer details Please ask your...

Page 27: ...data may be lost We recommend you save this data elsewhere prior to sending the product for repair You should also be aware that rather than repairing goods we may replace them with refurbished goods of the same type or use refurbished parts in the repair process Please be assured though refurbished parts or replacements are only used where they meet ALDI s stringent quality specifications If at a...

Page 28: ...t does not work If you encounter problems with this product or if it fails to perform to your expectations make sure to contact our After Sales Support Centre on 1300 886 649 For an electronic copy of this manual go to www stirlingappliances com au and download a copy or contact our after sales support centre Instruction Manual Revision Index Version No Issue Date Description V1 0 12 July 2019 Ori...

Reviews: