1.

 

Put operator platform down! Step on platform careful not to hit 
the foot switch. DO NOT OPERATE UNIT WITH PLATFORM IN THE 
UP LOCKED POSITION! Serious bodily harm can occur. 

 

2.

 

Release Parking brake as shown in figure 10 . Tire damage can 
occur if parking brake is not released. 

 

3.

 

Push both steering controls forward, to move the unit forward. 
The more pressure applied, the greater the speed.  

 

4.

 

Pulling back on both steering controls will put the unit in reverse.  

 

5.

 

Reduce the speed of the left or right steering control while moving 
forward to turn left or right.

 

6.

 

Always set parking brake before stepping off or turning off the 
unit. 

 

 

 

 

 

Figure 10

 

Usage

 

1.

 

Lower aeration tines into the ground by holding the foot pedal 

down (figure 11) or switching the tine position switch to down. 

 

2.

 

Lock the tines in the up position by switching to transport. 

 

3.

 

Tines can remain in the ground when making wide gentle turns.  

For sharper turns and 180’s the tines must be lifted prior to 
turning this will prevent turf damage. 

 

4.

 

Always lift tines prior to transporting and crossing over concrete, 

tree roots, and other hard surfaces.

 

Summary of Contents for Quad-Aer

Page 1: ...Quad Aer Operator s Manual Need Help Factory Support 502 536 0716...

Page 2: ...and free of any defects Do not use this equipment if any guards or safety decals are not in place Perform an inspection of the unit before each use Ensure all fasteners are secure the tires are prope...

Page 3: ...these safety labels Signal word definitions DANGER indicates an imminently hazardous situation which if not avoided WILL result in death or serious injury WARNING indicates a potentially hazardous si...

Page 4: ...e checked daily Hydraulic Fluid Level Check Procedures 1 Place unit on level ground Locate the Site Glass on the hydraulic tank 2 Oil level should be half way up the glass If not please refer to the H...

Page 5: ...o filter P N 51563 Rub a small amount of new oil on the O ring of the new filter prior to installing 7 Add Synthetic 20W 50 QA3600 13qts QA3000 5qts and rein stall fill cap Note May take less if unit...

Page 6: ...th idler pulley and tighten bolt The timing belt tension arm has a location for a drive breaker bar to be in stalled Pull breaker bar with 20 ft lb of force and tighten bolts Remove breaker bar Figure...

Page 7: ...from hydrostatic motor 2 Turn rod end clockwise or counter clockwise to increase or decrease speed on that side Reverse Speed Limiter 1 Loosen bolt as shown in figure 6 and slide stop forward or back...

Page 8: ...Turn ignition key to position II until engine starts and release the key Figure 7 3 Turn off the Choke by push the choke knob down If equipped with EFI skip this step 4 Allow the unit to warm up and...

Page 9: ...nd until the foot pedal is depressed Traditionally having the tines default to UP is most coming Default down position can be ad vantages for users that typically do larger properties Tine Depth Tine...

Page 10: ...nit in reverse 5 Reduce the speed of the left or right steering control while moving forward to turn left or right 6 Always set parking brake before stepping off or turning off the unit Figure 10 Usag...

Page 11: ...ior to aerating Does the property have unground utilities invisible dog fence low voltage lighting irrigation etc Calling 811 or a private locate services is strongly recommended and maybe the law Tak...