Maintenance
5
1000-hour maintenance/yearly maintenance
1000-hour maintenance/yearly maintenance
Other tasks
– Perform all tasks required to maintain
full operability; see the chapter entitled
"Remaining ready for operation".
6327_110-001
1 2
Checking the cable connections
– Check supply cable of pump motor (1) and
traction motor (2) for secure positioning,
condition and insulation .
NOTE
Oxidised connections and brittle cables lead
to voltage drops , so causing malfunctions.
– Remove oxidised connections and replace
brittle cables.
6327_003-045
1
Checking the hydraulic oil level of the
hydraulic battery carrier
WARNING
Hydraulic oils are hazardous to your health and are
under pressure during operation.
– Note safety regulations for working with hydrau-
lic oils; see ⇒ Chapter "Hydraulic fluid", P. 2-51.
Checking the hydraulic oil level
– Park the forklift truck on level ground.
– Remove the battery (see ⇒ Chapter "Re-
placing the battery with the hydraulic bat-
tery carrier", P. 4-345) and place it next to
the truck so that the battery male connector
can be inserted again.
The minimum distance between the battery
and the truck should be > 0.5 m. This is to
171533 EN - 02/2019 - 19
411
Summary of Contents for RX60-35/600
Page 2: ......
Page 4: ......
Page 14: ......
Page 15: ...1 Foreword ...
Page 38: ...1 Foreword Environmental considerations 24 171533 EN 02 2019 19 ...
Page 39: ...2 Safety ...
Page 71: ...3 Overviews ...
Page 73: ...Overviews 3 General view 171533 EN 02 2019 19 59 ...
Page 86: ...3 Overviews Operating devices and display elements 72 171533 EN 02 2019 19 ...
Page 87: ...4 Operation ...
Page 384: ...4 Operation Decommissioning 370 171533 EN 02 2019 19 ...
Page 385: ...5 Maintenance ...
Page 392: ...5 Maintenance General maintenance information 378 171533 EN 02 2019 19 ...
Page 396: ...5 Maintenance General maintenance information 382 171533 EN 02 2019 19 ...
Page 432: ...5 Maintenance 1000 hour maintenance yearly maintenance 418 171533 EN 02 2019 19 ...
Page 433: ...6 Technical data ...
Page 458: ...6 Technical data Fuse assignment 444 171533 EN 02 2019 19 ...
Page 469: ......
Page 470: ...STILL GmbH 171533 EN 02 2019 19 ...