Checking the condition of cables,
terminals and battery connector
–
Check that the cable insulation is undam-
aged and that there are no signs of over-
heating at the connections.
–
Check that the "+" and "-" output terminals
are not sulphated (presence of white salt).
–
Check the condition of the battery connec-
tor contacts and the presence of the keying
pin.
–
If the truck is equipped with an on-board
charger, check the condition of the spindles
of the mains socket. No oxidation must be
present and the wires must not be dam-
aged.
CAUTION
The points mentioned above can cause serious inci-
dents. In case of an incident, contact our service en-
gineers as quickly as possible.
Servicing the pump motor
Checking the electrical connections
–
Check the mounting, condition and insula-
tion of the pump motor cables (1).
–
Eliminate any traces of oxidation.
–
Replace faulty cables.
NOTE
Oxidised connections and faulty cables will re-
sult in a drop in voltage, leading to malfunc-
tions.
Maintenance
5
Electrical equipment
112
1160 801 15 51 EN - 02/2021 - 11
Summary of Contents for EXD 18
Page 2: ......
Page 4: ......
Page 10: ......
Page 11: ...1 Introduction ...
Page 20: ...Introduction 1 Disposing of components and batteries 10 1160 801 15 51 EN 02 2021 11 ...
Page 21: ...2 Safety ...
Page 31: ...3 Overviews ...
Page 40: ...Overviews 3 Markings 30 1160 801 15 51 EN 02 2021 11 ...
Page 41: ...4 Use ...
Page 102: ...Use 4 Handling the truck in specific situations 92 1160 801 15 51 EN 02 2021 11 ...
Page 103: ...5 Maintenance ...
Page 132: ...Maintenance 5 Commissioning and storage 122 1160 801 15 51 EN 02 2021 11 ...
Page 133: ...6 Technical specifications ...
Page 140: ...Technical specifications 6 Mast types 130 1160 801 15 51 EN 02 2021 11 ...
Page 144: ......
Page 145: ......