Picking up a load at height
–
Carefully drive the machine to the required
location.
–
Raise the forks to the height of the pallet.
–
Carefully move the forks forward under the
pallet.
–
Lift the forks until the pallet moves away
from the racking.
–
Reverse the truck to free the pallet.
–
Lower the goods again until they are a few
centimetres away from the ground.
CAUTION
If the equipment has an initial lift control, separate
the goods from the racking. To maintain maximum
stability, never use the initial lift control, to avoid
overloading the equipment.
Emergency lowering
The solenoid valve is equipped with an emer-
gency lowering screw for manual emergency
lowering.This operation can be executed if the
hydraulic system develops a fault.The sole-
noid valve with the emergency lowering screw
is located on the valve body of the hydraulic
pump.
CAUTION
Do not stand in the vicinity of the forks when the fork
arms are being lowered.
Always keep your hands on the screw during lower-
ing, so you can stop the lowering operation at any
time.
Operation
4
Hydraulic operations
62
50028011505 EN - 03/2022 - 06
Summary of Contents for ECV 10
Page 2: ......
Page 4: ......
Page 9: ...1 Introduction ...
Page 28: ...Introduction 1 Residual risks 20 50028011505 EN 03 2022 06 ...
Page 29: ...2 Safety ...
Page 42: ...Safety 2 EMC Electromagnetic compatibility 34 50028011505 EN 03 2022 06 ...
Page 43: ...3 Views ...
Page 51: ...4 Operation ...
Page 76: ...Operation 4 Transporting the truck 68 50028011505 EN 03 2022 06 ...
Page 77: ...5 Maintenance ...
Page 85: ...Lubrication point Maintenance 5 Maintenance work 77 50028011505 EN 03 2022 06 ...
Page 94: ...Maintenance 5 Malfunction analysis 86 50028011505 EN 03 2022 06 ...
Page 95: ...6 Technical data ...
Page 105: ......