0000-GXX-0010-A0 KN
► Put the strap over your left shoulder so that
the unit hangs at your side.
► Operate the gun and always pay attention to
the optimal working pressure while spraying.
► If the working pressure drops more than
0.5 bar (7.25 PSI) , restore it by operating the
pump handle.
8
After Spraying
► Completely depressurize the tank.
► Unscrew the pump from the tank.
► Drain the tank in a well-ventilated location –
collect remaining solution in a suitable con‐
tainer.
Dispose of any residual spray solution in accord‐
ance with environmental requirements – follow
instructions of chemical manufacturer.
► Rinse the tank with clean water.
► Fill the tank with clean water, pump and spray
until the tank is empty and completely depres‐
surized.
► Wipe down the whole unit with a damp cloth.
9
Storing the Machine
► Keep tank and pump separate for drying and
storage.
► Dry the unit and store it in a place protected
from direct sunlight and frost.
10 Inspection and Mainte‐
nance by User
10.1
Pump
Removing
► Unscrew the pump from the tank.
► Hold pump firmly by the cylinder barrel and
unlock the pump handle.
6159BA015 KN
2
3
4
1
► Pull the pump handle (1) out of the cylinder
barrel (2) as far as stop.
► Pull pump handle and rotate it counterclock‐
wise until the gland (3) is released from the
cylinder barrel.
► Pull the piston rod (4) out of the cylinder bar‐
rel.
6159BA016 KN
► Lubricate the piston cup seal and O-ring with a
food-safe grease.
8 After Spraying
English
0458-583-0121-B
9