![Stihl RE 271 Instruction Manual Download Page 55](http://html1.mh-extra.com/html/stihl/re-271/re-271_instruction-manual_1379595055.webp)
RE 271, RE 271 PLUS, RE 281, RE 281 PLUS
English
53
Electrical Specifications
RE 271, RE 271 PLUS
RE 281, RE 281 PLUS
Hydraulic specifications
RE 271, RE 271 PLUS
RE 281, RE 281 PLUS
Specifications
Power supply:
1)
Australia, New Zealand only
2)
Great Britain only
230 V / 1~ / 50 Hz
230 V - 240 V
1~ / 50 Hz
1)
Power output:
3.2 kW
2.3 kW
1)
2.9 kW
2)
Ampere rating:
14 A
10 A
1)
13 A
2)
Fuse (character
-
istic "C" or "K"):
16 A
10 A
1)
13 A
2)
Protection class: I
Type of
protection:
IP X5
Power supply:
400 V / 3~ / 50 Hz
400 V - 415 V
3~ / 50 Hz
3)
230 V / 3~ / 50 Hz
4)
200 V / 3~ / 50 Hz
5)
200 V / 3~ / 60 Hz
6)
Power output:
4.2 kW
4 kW
5) 6)
Ampere rating:
8 A
13 A
4)
15 A
5) 6)
Fuse (character
-
istic "C" or "K"):
16 A
15 A
5) 6)
Protection class: I
Type of
protection:
IP X5
3)
Malaysia only
4)
Norway only
5)
Japan only (50 Hz version)
6)
Japan only (60 Hz version)
Working pressure:
2 - 14 MPa
(20 - 140 bar)
2 - 12 MPa
1) 2)
(20 - 120 bar)
Max. permissible
pressure:
25 MPa
(250 bar)
Max. water feed
pressure:
1 MPa
(10 bar)
Max. water
throughput:
660 l/h
530 l/h
1)
660 l/h
2)
Water throughput, as
per EN 60335-2-79:
600 l/h
500 l/h
1)
620 l/h
2)
Max. suction lift:
1 m
Max. water feed temperature
With pressurized
water supply:
60 °C
Suction operation:
50 °C
Max. kickback force: 28 N
22 N
1)
27 N
2)
1)
Australia, New Zealand only
2)
Great Britain only
Working pressure:
5)
Japan only (50 Hz version)
6)
Japan only (60 Hz version)
2 - 16 MPa
(20 - 160 bar)
2 - 15 MPa
5) 6)
(20 - 150 bar)
Max. permissible
pressure:
25 MPa
(250 bar)
Max. water feed
pressure:
1 MPa
(10 bar)
Max. water
throughput:
760 l/h
Water throughput, as
per EN 60335-2-79: 700 l/h
Max. suction lift:
1 m
Max. water feed temperature
With pressurized
water supply:
60 °C
Suction operation:
50 °C
Max. kickback force: 35 N
34 N
5) 6)