66
MS 661, MS 661 C-M
Checking wires between
solenoid valve unit and
diagnostic socket
– Connect test cable,
:
Pull connector (1) off the solenoid
valve (2).
:
Measure resistance between red
wire (1) on the solenoid valve's
connector and test cable's black
plug (2).
Specified value: < 10
Ω
1166RA236 TG
2
1
1166RA274 TG
1
2
:
Measure resistance between
black wire (1) on the solenoid
valve's connector and test
cable's red plug (2).
Specified value: < 10
Ω
If the specified values are not
obtained
– Check contact faces on the plug
and connector tag, and wires for
break, or contact between cable
lug / terminal socket, replace
switch unit if necessary,
– Reassemble all other parts in the
reverse sequence.
8.4
Wiring Harness
The wires of the M-Tronic and the
short circuit wire are combined in a
wiring harness. Removal and
installation are described in the
chapter on "Wiring Harness with M-
Tronic / Heating, Removing and
Installing,
1166RA275 TG
1
2
8.5
Switch Unit
– Remove the filter base,
– Test the switch unit,
:
Remove the connector (1) from
the solenoid valve (2) – do not
tug wires to remove the
connector.
:
Take out the screws (1) and
remove the switch unit (2).
:
Check lever on choke shaft (3),
replace if necessary,
1166RA236 TG
2
1
1166RA276 TG
1
2
3
1