12
English / USA
HL 75, HL 75 K
Mounting the Loop Handle
Not necessary on 0° fixed angle
version
with
handle hose
on the
drive tube.
:
Fit the square nuts (
1
) in the barrier
bar (
2
) – the holes must line up.
:
Fit the clamp (
3
) in the loop
handle (
4
) and place them both
on the drive tube (
5
).
:
Place clamp (
6
) in position and fit
the barrier bar (
2
) so that the holes
line up.
:
Insert screws (
7
)
and tighten them
down moderately against the barrier
bar.
:
Align the loop handle (
4
) and move
it to the most comfortable position.
On
HL 75 K
, distance
A
must not be
more than 30 cm (12”) – about
25 cm (10”) is recommended.
On
HL 75
, distance
A
must not be
more than 55 cm (22”) – about
35 cm (14”) is recommended
:
Tighten down the screws (
7
)
securely.
Assembling the Unit
1
1
2
2
1
1
389BA001 KN
7
7
6
5
3
4
2
389BA002 KN
389BA042 KN
4
A