background image

longer function properly or safety devices may

be rendered inoperative. They may cause seri‐

ous injury to persons.

► Clean the blower, battery and charger as

described in this instruction manual.

■ If the blower, battery or charge are not serv‐

iced or repaired correctly, components may no

longer function properly or safety devices may

be rendered inoperative. This may result in

serous or fatal injury to people.

► Do not attempt to service or repair the

blower, battery or charger.

► If the blower, battery or the charger require

servicing or repairs: Contact your STIHL

servicing dealer for assistance.

5

Preparing the Blower for

Operation

5.1

Preparing the Blower for Oper‐

ation

The following steps must be performed before

commencing work:

► Ensure that the following components are in

safe condition:

Blower,   4.6.1.

Battery,   4.6.2.

Charger,   4.6.3.

► Check the battery,   10.2.

► Fully charge the battery,   6.2.

► Clean blower,   15.1.

► Attach nozzle,   7.1.

► Check the controls,   10.1.

► If it is not possible to carry out these steps do

not use the blower. Consult a STIHL servicing

dealer.

6

Charging the Battery, LEDs

6.1

Mounting the Charger on a

Wall

The charger can be mounted on a wall.

d

a

1

2

a

e

e

b

3

0000099636_001

Check the following points

when mounting the charger on

a wall:

Suitable fixing materials.

The charger is level.

The following dimensions are observed:

a = at least 100 mm

b (for AL 101) = 75 mm

b (for AL 301) = 100 mm

b (for AL 500) = 120 mm

c = 4.5 mm

d = 9 mm

e = 2.5 mm

6.2

Charging the Battery

The charging time depends on various factors,

e.g. the battery temperature or the ambient tem‐

perature. For optimum performance, observe the

recommended temperature ranges,   18.6. The

actual charging time may vary from the charging

time indicated. The charging time is indicated at

www.stihl.com/charging-times.

The charging process starts

automatically when the mains

plug is plugged into a socket

and the battery is inserted into

the charger. The charger

switches off automatically when

the battery is fully charged.

The battery and the charger warm up during

charging.

7

6

5

3

2

4

1

0000-GXX-0628-A0

► Plug the mains plug (6) into an easily accessi‐

ble socket (7).

The charger (3) will run a self-test. The

LED (4) will glow green for about 1 second

and red for about 1 second.

► Routing the connecting cord (5).

English

5 Preparing the Blower for Operation

10

0458-807-0121-B

Summary of Contents for BGA 57

Page 1: ...BGA 57 2 18 Instruction Manual...

Page 2: ...resources This user manual is intended to help you use your STIHL product safely and in an environmentally friendly manner over a long service life We thank you for your confidence in us and hope you...

Page 3: ...e plug 16 Appliance Plug Connects cable to wall outlet Rating Label with Serial Number 3 2 Symbols Meanings of symbols that may be on the blower battery and charger 1 LED glows red Battery too hot or...

Page 4: ...or which they were not designed may result in serious or fatal injuries and dam age to property Use the blower battery and charger as described in this User Manual 4 3 The Operator WARNING Users witho...

Page 5: ...ot allow bystanders children or animals within 5 meters of the work area Maintain a clearance of 5 meters from objects Do not leave the blower unattended Ensure that children cannot play with the blow...

Page 6: ...r operate correctly and safety devices may be disabled This may result in serous or fatal injury to people Never use a damaged blower If the blower is dirty or wet Clean the blower and allow it to dry...

Page 7: ...damage to property may occur Do not direct the air blast towards bystand ers animals or objects If the behavior of the blower changes during operation or feels unusual it may no longer be in a safe c...

Page 8: ...ension cord so that they will not be damaged kinked or crushed and will not be chafed Protect the connecting cable and extension cord from heat oil and chemicals Lay the connecting cable and extension...

Page 9: ...a state of charge between 40 and 60 2 lit green LEDs Do not store the battery outside of the specified temperature limits 18 6 4 11 3 Charger WARNING Children are not aware of and cannot assess the d...

Page 10: ...the Battery LEDs 6 1 Mounting the Charger on a Wall The charger can be mounted on a wall d a 1 2 a e e b 3 0000099636_001 Check the following points when mounting the charger on a wall Suitable fixin...

Page 11: ...y is being charged If the LED flashes red Rectify the malfunction Malfunction in charger 7 Assembling the Blower 7 1 Mounting Adjusting and Removing the Nozzle The nozzle can be mounted to the blower...

Page 12: ...se slide or trigger lockout is faulty Push the release slide in the direction of the blower tube with your thumb and hold it there Depress the trigger lockout lever and hold it in that position Pull t...

Page 13: ...gulations The battery is classified as UN 3480 lithium ion batteries and has been tested pursuant to UN Manual Tests and Criteria Part III Subsection 38 3 The transport regulations can be found at www...

Page 14: ...ign objects from the battery com partment and clean the battery compartment with a damp cloth Clean the electrical contacts in the battery compartment with a paintbrush or soft brush 15 2 Cleaning the...

Page 15: ...lectrical connection between the blower and the battery Remove the battery Clean electrical contacts in the battery compartment Insert battery The blower or the bat tery is damp Allow blower or batter...

Page 16: ...he battery is exposed to cer tain environmental conditions it may catch fire or explode This may result in serious injury to people and damage to property Do not charge the battery below 20 C or above...

Page 17: ...d Charger Contact the local authorities or your STIHL dealer for information on disposal Improper disposal can be harmful to health and pollute the environment Take STIHL products including packaging...

Page 18: ...nd ards in the versions valid on the date of produc tion EN 55014 1 EN 55014 2 EN 60335 1 and EN 50636 2 100 Zur Ermittlung des gemessenen und des garan tierten Schallleistungspegels wurde nach UK Ver...

Page 19: ...22 UKCA Declaration of Conformity English 0458 807 0121 B 19...

Page 20: ...www stihl com 04588070121B 04588070121B 0458 807 0121 B 0458 807 0121 B...

Reviews: