background image

Installation Safety

»  

Always consult local and state building codes and other applicable standards and regulations before begin-

ning a solar collector installation.

»  

Adhere to all applicable codes and standards during installation. Special consideration must be given to build-

ing code requirements for the penetration of structural members and 

fi

re rated assemblies.

»  

Ensure that the mounting surface to which the collector(s) will be attached are structurally sound and capable 

of supporting the load of the collector(s).

»  

Read and follow all labels/markings on the ladder.  Always inspect the ladder prior 

to using it. If the ladder is damaged, it must be removed from service and tagged 
until repaired or discarded. 

»  

Do not use the top step/rung of a ladder as a step/rung unless it was designed for 

that purpose

»  

Only use ladders and appropriate accessories (ladder levelers, jacks or hooks) for 

their designed purposes. 

»  

An extension or straight ladder used to access an elevated surface must extend at 

least 3 feet above the point of support (see diagram). Do not stand on the three top 
rungs of a straight, single or extension ladder. 

»  

The proper angle for setting up a ladder is to place its base a quarter of the work-

ing length of the ladder from the wall or other vertical surface (see diagram). 

»  

Be sure that all locks on an extension ladder are properly engaged. 

»  

Do not exceed the maximum load rating of a ladder. Be aware of the ladder’s load 

rating and of the weight it is supporting, including the weight of any tools or equipment. 

»  

A ladder placed in any location where it can be displaced by other work activities must be secured to prevent 

displacement or a barricade must be erected to keep traf

fi

c away from the ladder. 

3-f

t. min.

x

Distance t

o top suppor

t

x/4

PRODUCT & SAFETY RISKS

This product has been manufactured to provide the highest  level of performance and reliability. Nevertheless, 
there can still be risks associated with installing, using and maintaining this product.

Dangers can arise from

»  

Components of the collector become very hot during operation (will burn when touched)

»  

Other risks may originate from broken glass (cut injury)

»  

Spurting hot 

fl

uid and 

fl

owing steam (scalding injury) 

»  

Falling when working on the roof

The Stiebel Eltron S-Power Performance Series HP evacuated-tube solar collector must be installed and put into 
operation in accordance with this instruction manual. It must be used exclusively for the described purpose. If used
other than the described purpose (abusive use), dangers for persons can arise and the collector can be damaged. 
Misuse of this product can be, for example, 

fi

lling the collector with other substances than an appropriate heat

 

transfer medium or the installation on surfaces that are not suf

fi

ciently stable.

ALTERATIONS AND CHANGES APART FROM THOSE DESCRIBED IN 

THE INSTRUCTION MANUAL ARE NOT ALLOWED.

05

Summary of Contents for S-Power SP-20

Page 1: ...the S Power vacuum tubes From glass factory to finished high performance vacuum tubes HighTech Made in Germany Solar Keymark Installation instructions Heat Pipe PERFORMANCE SERIES S Power Heat Pipe C...

Page 2: ...Simply the Best Prior to installation please check for updates to this document at www stiebel eltron usa com install html S Power Performance Series Instruction Manual Rev April 2012...

Page 3: ...s situation which if not avoided could result in minor or moderate injury NOTICE NOTICE is used to address practices not related to personal injury This symbol is used when there is a risk of of burni...

Page 4: ...Do not talk on your cell phone eat drink or chat unnecessarily while you are on the rooftop or ladder If it is windy or rainy delay the project Working at height with wet ladder steps and on slick sur...

Page 5: ...re properly engaged Do not exceed the maximum load rating of a ladder Be aware of the ladder s load rating and of the weight it is supporting including the weight of any tools or equipment A ladder pl...

Page 6: ...tem has to be connected to the building s ground over short runs for both the feed and the return lines Handling Glass Tubes WARNING The glass tubes have a vacuum Damage due to external pressure loadi...

Page 7: ...e is danger of falling Please con sider the accident prevention regulations e g OSHA and use appropriate safeguards Personal Risk of Falling Objects WARNING During installations on the roof there is a...

Page 8: ...fication WHO IS ALLOWED TO INSTALL SOLAR COLLECTORS The following aspects should be considered when planning a system What energy will be consumed in what period of time Will demand consumption be con...

Page 9: ...tructions for Required tools Possible installation types Facade Pitch roof Folded seam roof corrugated metal roof Caution The collectors are to be installed so that the distributor tube is in the top...

Page 10: ...3 Install on wall or fa ade Install on corrugated metal Mark drill insert wall plug install cap profile with key screw NW 13 nm mount with suitable screws for corrugated metal and flat roof installati...

Page 11: ...ches 37 75 inches 38 75 inches 55 5 inches 11 Installation instructions SP 20 SP 30 Stiebel Eltron Inc 17 West Street West Hatfield MA 01088 Telephone 800 582 8423 Fax 413 247 3369 info stiebel eltron...

Page 12: ...6 Place the safety rubber ring on top of the glass metal connection Rotate constantly the s power high performance heat pipe tube while inserting into the hole in the collector casing Insert the tube...

Page 13: ...porting bracket Collector casing 15 15 Recommendation The casing may be mounted to the supporting bracket even before inserting the tubes as the tube is lockable by itself 13 Installation instructions...

Page 14: ...verted connections the adapter Art No 791069 should be used 18 19 20 21 22 23 On the left hand side lubricate the o ring of the collector connection with silicone grease connect the corrugated hose pu...

Page 15: ...ANTIES THE WARRANTY PRINTED ABOVE IS THE ONLY WARRANTY APPLICABLE TO THIS PURCHASE ALL OTHER WARRANTIES EXPRESS OR IM PLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND F...

Page 16: ...sa com Internet www stiebel eltron usa com We are available for questions concerning the installation of our high quality vacuum tube collectors at any time Stiebel Eltron Inc 17 West Street West Hatf...