background image

24

 | PSH  Trend www.stiebel-eltron.com

inSTALLATion 

 

Speciication

Wall mounting bracket

30 - 50 l

184

265

300

360

8

0�

0

2

�0

7�

0

0

0

5

80 - 200 l

450

415

360

350

300

265

8

0�

0

2

�0

7�0

0

0

6

15.2  Wiring diagram

N

L

2

1

3

4

5

6

7

8

8

5

�0

2

�0

7�

0

01

0

1  Terminal
2  High limit safety cut-out
3  Temperature controller
4  ON/OFF indicator
5  Heating element
6  Electrical resistance 560 ohm
7  Anode
8  Cylinder

15.3  Heat-up diagrams

The heat-up time depends on the cylinder capacity, cold water 
inlet temperature and heating output.

Graph assumes 15 °C cold water inlet temperature:

0

1

2

3

4

5

6

35

45

55

65

75

1

2

7

6

5

4

3

D

00000

37

21

4

X  Temperature setting [°C]
Y  Heat-up time [h]
1  150 l
2  200 l
3  120 l
4  100 l
5  80 l
6  50 l
7  30 l

15.4  Fault conditions

In the event of a fault, temperatures of up to 95 °C at 0.6 MPa 
can occur. 

Summary of Contents for PSH 100 Trend

Page 1: ...alacja geschlossener Warmwasser Wandspeicher sealed unvented wall mounted dhW cylinder chauffe eau mural ecs sous pression gesloten warmwaterboiler voor wandbevestiging tlakov n st nn z sobn k tepl vo...

Page 2: ...g the safety valve 22 14 2 Draining the appliance 22 14 3 Checking replacing the protective anode 22 14 4 Descaling 22 14 5 Anti corrosion protection 22 14 6 Replacing the power cable 22 14 7 Replacin...

Page 3: ...contractors The chapter Installation is intended for qualified contractors Note Read these instructions carefully before using the appli ance and retain them for future reference Pass on the instruct...

Page 4: ...be used by children aged 8 and up and persons with reduced physical sensory or mental capa bilities or a lack of experience and know how provided that they are supervised or they have been instructed...

Page 5: ...fter f f Never use abrasive or corrosive cleaning agents A damp cloth is suficient for cleaning the appliance Scaling f f Almost every type of water will deposit lime at high temper atures This settle...

Page 6: ...load bearing ca pacity There should be a suitable drain near the appliance to drain off the expansion water Always install the appliance vertically in a room free from the risk of frost and near the...

Page 7: ...lve is fully opened f f Fit the discharge pipe of the safety valve with a constant downward slope and in a room free from the risk of frost f f The safety valve discharge aperture must remain open to...

Page 8: ...ng f f hand over these instructions 11 2 Recommissioning see chapter Commissioning 12 Shutting down f f Disconnect the appliance from the mains at the MCB fuse in the fuse box f f Drain the appliance...

Page 9: ...anode f f Check the protective anode after the first year of use and re place if necessary f f Next decide the time intervals at which further checks should be carried out 14 4 Descaling f f Remove lo...

Page 10: ...410 520 520 520 520 520 a40 Appliance Diameter mm 405 405 510 510 510 510 510 b01 Entry electrical cables Threaded fitting M20x1 5 PG 16 M20x1 5 PG 16 M20x1 5 PG 16 M20x1 5 PG 16 M20x1 5 PG 16 M20x1...

Page 11: ...FF indicator 5 Heating element 6 Electrical resistance 560 ohm 7 Anode 8 Cylinder 15 3 Heat up diagrams The heat up time depends on the cylinder capacity cold water inlet temperature and heating outpu...

Page 12: ...ata standby energy consumption 24 h at 65 C kWh 0 53 0 72 0 79 0 98 1 14 1 33 1 61 Versions Colour White White White White White White White iP rating iP25 iP25 iP25 iP25 iP25 iP25 iP25 sealed unvente...