MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS |
11
INSTALLATION
TECHNICAL DATA
11. Technical data
Model
Mini
2
*
Mini
2.5
Mini
3
Mini
3.5
Mini
4
Mini
6
Item number
231045
232098
220816
232099
222039
220817
Phase
1
1
1
1
1
1
Voltage
V
115 - 125
115 - 125
115 - 125
115 - 125
208
240
208
240
Wattage
kW
1.8
2.4
3.0
3.5
2.9
3.5
4.7
5.7
Max. amp, load
A
16
21
25
31
13.8
15.2
22.4
24.7
Min. required
circuit breaker size
A
20
30
30
40
20
20
30
30
Required wire size
AWG COPPER
12
10
10
10
12
12
10
10
Min. water flow to
activate unit
≥
GPM
(
≥
l/min)
0.21
(0.8)
0.40
(1.5)
0.40
(1.5)
0.40
(1.5)
0.40
(1.5)
0.77
(2.9)
Recommended
inlet temp. range
°F (°C)
41-77 (5-25)
Nominal water
volume
GAL (l)
0.026 (0.1)
Working pressure,
max.
PSI (bar)
150 (10)
Tested to pressure
PSI (bar)
300 (20)
Weight
lbs. (kg)
3.44 (1.56)
Dimensions
Height
Depth
Width
inch (mm)
inch (mm)
inch (mm)
6
1
/
2
(165)
3
1
/
4
(82)
7
1
/
2
(190)
Water connections
for 3/8“ O.D. flex connector
Heating System
Nichrome bare-wire
* Note: Mini 2 is internally restricted to 0.32 GPM
-Tankless water heaters are considered a non-continuous load
-Conductors should be sized to maintain a voltage drop of less than 3 % under load
-For use with cold water supply only
12. Troubleshooting
E
Symptom
Possible cause
Solution
No hot water
despite fully
opened hot
water faucet
.
No electrical power
.
Check the circuit breaker and
check voltage at the wiring block
.
The activation fl ow rate needed to
turn on the heating element has not
been reached.
Clean fi lter screen
.
Safety cut out tripped
– turn circuit breakers off
– open Hot Valve to release pres-
sure from the unit
– reset saftey pressure cut out
E
– turn circuit breakers on