INSTALLATION  

WATER CONNECTIONS

8.4 Mounting

 

Securely install the appliance in a location affording easy pip-
ing to the hot water tank.

 

Install appliance in a frost free area. If frost may occur, remove 
appliance before freezing temperatures set in.

 

Leave a minimum of 5” of clearance on all sides for servicing.

26

_0

2

_02

_1

0

8

3

 

Remove plastic cover.

2

6

_0

2_0

2

_0

3

3

1

26

_0

2

_02

_1

0

9

0

 

Screw the screws into the wall and hang the appliance. Screws 
and plastic wall anchors for mounting on masonry or wood are 
provided.

 

Secure the screws.

9. Water 

connections

!

 

Damage to the appliance and the environment:

Excessive heat from soldering on copper pipes near the 
MegaBoost may cause damage.

 

All plumbing work must comply with national and applicable 
state and local plumbing codes.

 

A pressure reducing valve must be installed if the cold water 
supply pressure exceeds 150 PSI (10 bar).

 

Make certain that the cold water supply line has been fl ushed 
to remove any scale and dirt.

 

Install isolating valve in cold water line as shown in 8.3, “Typi-
cal installation confi gurations”, pg. 5. This allows the appli-
ance to be isolated for maintenance purposes. The tank water 
heater should have its own isolation valve in addition to the 
valve for the MegaBoost.

 

Cold water connection (inlet) is on the right side of the ap-
pliance, hot water connection (outlet) is on the left side of 
appliance.

 

Tankless water heaters such as the MegaBoost are not required 
to be equipped with a Pressure and Temperature Relief Valve 
(P&T). If the local inspector will not pass the installation with-
out a P&T, it should be installed on the hot water outlet side of 
appliance.

 

The appliance is designed for connection to copper tubing, PEX 
tubing or a braided stainless steel hose with a ½“ NPT female 
tapered thread. If soldering near the appliance is necessary, 
please direct the fl ame away from the plastic housing of the 
appliance in order to avoid damage. Two couplings that adapts 
½˝ to ¾˝ NPT are included with the MegaBoost.

 

When all plumbing work is completed, check for leaks and take 
corrective action before proceeding.

10. Electrical connection

 

DANGER: Electrocution
Carry out all electrical connection and installation work in 
accordance with relevant regulations.

 

DANGER: Electrocution
Only use a permanent connection to the power supply. The 
appliance must be able to be separated from the power 
supply by an isolator that disconnects all poles with at least 
3 mm contact separation.

Summary of Contents for MEGABOOST

Page 1: ...105 F 120 F Residential Use 120 F 140 F Commercial Only F C Tankless electric booster for tank water heaters Off The MegaBoost is tested and certified by WQA against NSF ANSI 372 for lead free compliance STIEBEL ELTRON Inc 17 West Street West Hatfield MA 01088 Tel 413 247 3380 Fax 413 247 3369 Email info stiebel eltron usa com www stiebel eltron usa com ...

Page 2: ...7 10 2 Terminal block_______________________________________________________ 7 11 Commissioning _________________________________________________ 8 11 1 Appliance handover________________________________________________ 8 12 Troubleshooting ________________________________________________ 8 12 1 Display options LED diagnostic traffic lights ________________ 8 12 2 Fault table_______________________...

Page 3: ...ice technicians DANGER Electrocution Before proceeding with any installation adjustment al teration or service of this appliance all circuit breakers and disconnect switches servicing the appliance must be turned off Failure to do so could result in serious personal injury or death DANGER Electrocution Never remove the appliance cover unless the electricity servicing the appliance is turned off Fa...

Page 4: ...he appliance will deliver any water temperature between 86 F 30 C and 140 F 60 C Please set the desired temperature using the knob on the front cover Note For reasons of appliance efficiency and durability scaling the optimum temperature setting lies between 86 F 30 C and 120 F 50 C In case the Power light is flashing while the appliance operates the water flow rate exceeds the heating capacity of th...

Page 5: ...eater CAUTION Electrocution Unit must be installed in a vertical position with the water fittings pointing downward In this position the unit is splashproof so that no water can soak in 8 2 Choosing installation configuration The Megaboost can either pre heat an electric tank water heater or be pre heated by one The chart shows the effect of installation on the tank cold water inlet versus on the ta...

Page 6: ...ated for maintenance purposes The tank water heater should have its own isolation valve in addition to the valve for the MegaBoost Cold water connection inlet is on the right side of the ap pliance hot water connection outlet is on the left side of appliance Tankless water heaters such as the MegaBoost are not required to be equipped with a Pressure and Temperature Relief Valve P T If the local in...

Page 7: ...ections Then feed wires through strain relief clamp and tighten clamp down on wire The live wires must be connected to the slots on the terminal block marked L and L The ground wire must be connected to slot marked with the ground symbol Strain relief clamp with screws and rubber seal are provided 10 1 Temperature setting anti scalding protection 26_02_02_1089 Connect the lead of the electronic te...

Page 8: ... at tention to the safety information Hand the operating and installation instructions to the user 12 Troubleshooting DANGER Electrocution To test the appliance it must be supplied with power 12 1 Display options LED diagnostic traffic lights Display options red illuminates in case of faults yellow illuminates when the appliance is heating water green flashing The appliance is supplied with power 1...

Page 9: ... circuit breaker1 DP A 35 40 Min recommended wire size2 copper AWG 8 8 Min water flow to activate appliance GPM l min 0 26 1 Protection level according to IP 24 Max inlet water temperature F C 131 55 Nominal water volume GAL l 0 13 0 5 Working pressure max PSI bar MPa 150 10 1 Tested to pressure PSI bar MPa 300 20 2 Weight lbs kg 5 9 2 7 Water connections 1 2 NPT 1 This is our recommendation for o...

Page 10: ...ermal cut out 286369 3 Electronic control appliance 291851 4 Coding plug 283455 5 Back panel 292578 6 Flow sensor DFE 286461 7 Cold water connection 291699 8 Filter screen 252430 9 Hot water connection 278634 10 Plastic cover 11 Wiring block 279998 12 Axis connection plug 254312 13 Electronic temperature control 286359 14 Temperature adjustment knob 254307 15 Outlet temperature sensor 280677 ...

Page 11: ...as directed by Manufacturer and other than in accordance with applicable building codes 4 failure to maintain the Heater or to operate the Heater in accordance with the Manufacturer s specifications 5 operation of the Heater under fluctuating water pressure or in the event the Heater is supplied with non potable water for any duration 6 improper installation and or improper materials used by any ins...