EN
GL
ISH
www.stiebel-eltron.com
EBK | KBA |
19
OPERATION | INSTALLATION
Troubleshooting
6. Troubleshooting
Problem
Cause
Remedy
The appliance does not
heat up.
The appliance is not
plugged into the mains.
Insert the plug into the
mains socket.
The appliance is not
switched on.
Switch the appliance on.
The fuse/MCB has blown/
responded.
Check the fuse/MCB in
your fuse box/distribu-
tion panel.
There is no water in the
appliance.
Fill the appliance with
water.
The appliance switches
off before it reaches boil-
ing point.
The appliance is scaled
up.
Descale the appliance.
The hot water flow is
significantly reduced, de-
spite the draw-off valve
being fully open.
The appliance is scaled
or dirty.
Clean and descale the
appliance.
If you cannot remedy the fault, notify your qualified contractor.
To facilitate and speed up your request, provide the number from
the type plate (000000-0000-000000).
Typ:
Nr.:
-
-
EBK 5 K
000000 0000
5l K 0 MPa 10l/min
2kW 230V 50Hz 8,7A
Made in Germany
000000
26
�0
2�
04
�0
15
3
INSTALLATION
7. Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1 General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
7.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
8. Appliance description
The appliance heats DHW electrically. Once the selected temper-
ature has been reached, the temperature limiter switches the
appliance off.
8.1 Standard delivery
The following are delivered with the appliance:
- Fill/drain tap
- Wall mounting bracket
- Two screws, two rawl plugs, two washers
- Installation template
8.2 Accessories
Replacement drain taps, replacement pivoting spouts and drain
outlets with stench traps are available as accessories.
9. Preparations
9.1 Installation site
Always install the appliance vertically (oversink) in a frost-proof
room.
10. Installation
10.1 Appliance installation
See also chapter "Alternative installation methods".