6
| DHF C-AU www.stiebel-eltron.com
INSTALLATION
Safety
INSTALLATION
7. Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1 General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
!
Material losses
Observe the maximum inlet temperature. Higher tem-
peratures may damage the appliance. You can limit the
maximum inlet temperature by installing a central ther-
mostatic valve.
7.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
Note
The installation of this appliance shall conform to the
Plumbing Code of Australia (PCA), and the New Zealand
Building Code.
Protection rating IP 24 (splashproof) can only be guaranteed with
a correctly fitted cable grommet.
8. Appliance description
8.1 Standard delivery
The following are delivered with the appliance:
- Wall mounting bracket
- Installation template (in the centre section of these
instructions)
- 2 extensions
- 2 caps
- 2 tees
- 2 plugs
- 8 flat gaskets
- Strainer
- Plastic profile washer
- 2 cover guides (for installation on finished walls)
9. Preparation
9.1 Installation location
!
Material losses
Install the appliance in a room free from the risk of frost.
f
Always install the appliance vertically and near the draw-off
point.
The appliance is suitable for undersink and oversink installation.
Note
f
Mount the appliance on the wall. The wall must have
sufficient load bearing capacity.
Undersink installation
D
00000
42
70
5
1
2
1 Cold water inlet
2 DHW outlet
Oversink installation
D
00000
42
70
6
1
2
1 Cold water inlet
2 DHW outlet
9.2 Water installation
- Never operate with preheated water.
- No safety valve is required.
f
Flush the water line thoroughly.
f
Ensure that the flow rate for switching on the appliance is
achieved (see chapter "Specification / Data table", On). In-
crease the mains water pressure if the required flow rate is
not achieved with the draw-off valve fully opened.
Summary of Contents for DHF 13 C-AU
Page 9: ...DHF 13 C AU DHF 15 C AU Installation template ...
Page 10: ...383 mm ...
Page 11: ...D0000043269 398 mm ...
Page 12: ......