STIEBEL ELTRON DHE 18 AU Operation And Installation Download Page 21

EN

GL

ISH

www.stiebel-eltron.com 

DHE  AU | 

21

INSTALLATION | ENVIRONMENT AND RECYCLING

 

 

Specification

17.7  Data table

 

 

DHE 18 AU

DHE 27 AU

 

 

202658

202659

Electrical data
Rated voltage

V

380

400

415

380

400

415

Rated output

kW

16.2

18

19.4

23.5

26

28

Rated current

A

24.7

26

27

35.6

37.7

38.9

Fuse protection

A

25

25

32

40

Frequency

Hz

50/60

50/60

50/-

50/-

Phases

 

3/PE

3/PE

Max. mains impedance at 50 Hz

Ω

0.331

0.315

0.304

0.221

0.210

 

Resistivity ρ15 ≥

Ω cm

900

900

Conductivity 

σ

15 ≤

μS/cm

1111

1111

Connections
Water connection

 

G 1/2 A

G 1/2 A

Application limits
Max. permissible pressure

MPa

1

1

Max. inlet temperature for reheating

°C

55

55

Values
Max. inlet temperature (e.g. pasteurisation)

°C

70

70

On

l/min

>2.5

>2.5

Flow rate at 28 K

l/min

9.9 at 415 V

14.3 at 415 V

Flow rate at 50 K

l/min

5.6 at 415 V

8.0 at 415 V

Pressure drop for flow rate at 50 K (without flow limiter)

MPa

0.06

0.14

Hydraulic data
Nominal capacity

l

0.4

0.4

Versions
Adjustable connected load

 

-

-

Temperature settings

°C

Off, 20-60

Off, 20-60

Protection class

 

1

1

Insulating block

 

Plastic

Plastic

Heating system heat generator

 

Bare wire

Bare wire

Cover and back panel

 

Plastic

Plastic

Colour

 

White

White

IP rating

 

IP 25

IP 25

Dimensions
Height

mm

466

466

Width

mm

225

225

Depth

mm

116

116

Weights
Weight

kg

3.2

3.2

 

Note

The appliance conforms to IEC 61000-3-12. 

Guarantee

The guarantee conditions of our German companies do not 

apply to appliances acquired outside of Germany. In countries 

where our subsidiaries sell our products a guarantee can only 

be issued by those subsidiaries. Such guarantee is only grant-

ed if the subsidiary has issued its own terms of guarantee. No 

other guarantee will be granted.
We shall not provide any guarantee for appliances acquired in 

countries where we have no subsidiary to sell our products. 

This will not affect warranties issued by any importers.

Environment and recycling

We would ask you to help protect the environment. After use, 

dispose of the various materials in accordance with national 

regulations.

ENVIRONMENT AND RECYCLING

Summary of Contents for DHE 18 AU

Page 1: ...OPERATION AND INSTALLATION Fully electronically controlled comfort instantaneous water heater DHE 18 AU DHE 27 AU...

Page 2: ...ery 10 8 2 Accessories 10 9 Preparation 10 9 1 Installation site 10 9 2 Minimum clearances 10 9 3 Water installation 10 10 Installation 11 10 1 Standard installation 11 11 Commissioning 13 11 1 Prepar...

Page 3: ...e to 43 C using the internal anti scalding protection on the ap pliance When using preheated water ensure that the inlet temperature does not exceed 55 C In Australia the use of a temperature control...

Page 4: ...efully Symbol Meaning Material losses appliance damage consequential losses and environmen tal pollution Appliance disposal f f This symbol indicates that you have to do something The ac tion you need...

Page 5: ...to the selected temperature This occurs regardless of the inlet temperature If the appliance is operated with preheated water and the inlet temperature exceeds the selected temperature the inlet temp...

Page 6: ...perature flashes once to confirm 4 7 Inlet temperature information If the appliance is operated with preheated water and the inlet temperature exceeds the selected set temperature the inlet tem peratu...

Page 7: ...sec 4 Circulation boost program Shower your arms and legs with cold water to boost circulation Spray from the hands and feet towards the body You can then repeat this process with hot water WW KW 3 m...

Page 8: ...mote controls During unpairing rc0 appears on the display of the programming unit for 5 seconds then rc again 4 9 3 Deactivating the parameter menu f f Exit the menu item by pressing i and holding for...

Page 9: ...and repair of the appliance 7 1 General safety instructions We guarantee trouble free function and operational reliability only if original accessories and spare parts intended for the appliance are...

Page 10: ...n D0000056242 1 2 1 Cold water inlet 2 DHW outlet Oversink installation D0000057030 1 2 1 Cold water inlet 2 DHW outlet Note f f Mount the appliance on the wall The wall must have sufficient load bear...

Page 11: ...r back panel section forwards Preparing the power cable on unfinished walls for connection from below 160 30 D0000053273 1 1 Cable entry installation aid f f Prepare the power cable Fitting the wall m...

Page 12: ...outlet pipe from the pipework with flat gaskets to the extensions from the appliance Making the electrical connection WARNING Electrocution Carry out all electrical connection and installation work in...

Page 13: ...over should be turned the other way up for easier operation see chapter Installation alternatives Rotated appliance cover Fit the appliance cover D0000040777 1 2 3 4 1 Pipe knock out 2 Cover guides 3...

Page 14: ...ed from below short power cable IP 25 Finished walls IP 24 Water connection IP rating Unfinished walls IP 25 Other IP rating Installation with offset tiles IP 25 Rotated appliance cover IP 25 Horizont...

Page 15: ...ns Deburr any sharp edges with a file f f Route the power cable through the cable grommet f f Connect the power cable to the mains terminal 13 4 Water installation on unfinished walls 12 D0000053319 f...

Page 16: ...ersink installation D0000073012 f f Remove the programming unit from the appliance cover by pressing the locking hooks and removing the programming unit f f Turn the appliance cover not the appliance...

Page 17: ...e appliance cover must be provided with a condensate drain opening of min 5 0 mm to max 6 0 mm at the marked po sition 50 5 0 D0000076914 1 2 1 Appliance cover with opening for condensate drain 2 Back...

Page 18: ...atch set value Tap faulty Replace tap Outlet sensor faulty Replace outlet sensor Heating system faulty Replace the function module PCB faulty Replace the function module Green flashes yellow flashes r...

Page 19: ...e can freeze and cause damage Clean strainer If the strainer in the threaded cold water fitting is dirty clean it Close the shut off valve in the cold water inlet line before remov ing cleaning and re...

Page 20: ...l min Rated voltage Cold water inlet temperature 380 V 400 V 415 V 5 C 10 C 15 C 20 C DHE 18 AU 16 2 5 1 5 8 6 6 7 7 18 0 5 7 6 4 7 3 8 6 19 4 6 2 6 9 7 9 9 2 DHE 27 AU 23 5 7 5 8 4 9 6 11 2 26 0 8 3...

Page 21: ...city l 0 4 0 4 Versions Adjustable connected load Temperature settings C Off 20 60 Off 20 60 Protection class 1 1 Insulating block Plastic Plastic Heating system heat generator Bare wire Bare wire Cov...

Page 22: ...t was not installed and commissioned a in Australia b in accordance with the Operating and Installation Guide and c in accordance with the relevant statutory and local require ments of the State or Te...

Page 23: ...ENGLISH www stiebel eltron com DHE AU 23 NOTES...

Page 24: ...TIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 F...

Reviews: