background image

BEDIENUNG UND INSTALLATION
OPERATION AND INSTALLATION
UTILISATION ET INSTALLATION
BEDIENING EN INSTALLATIE
OBSLUHA A INSTALACE

بيكرتلاو لامعتسلاا

Elektronisch geregelter Komfort-Durchlauferhitzer | Electronically controlled 
comfort instantaneous water heater | Chauffe-eau instantané confort à régulation 
électronique | Elektronisch geregelde comfort-doorstromer | Elektronicky 

regulovaný komfortní průtokový ohřívač

 | 

 

اًينورتكلإ هطبض متي يذلا حيرملا يروفلا ءاملا ناخس

»

DHB-E 11/13 LCD

»

DHB-E 18 LCD 25A

»

DHB-E 18/21/24 LCD

»

DHB-E 27 LCD

Summary of Contents for DHB-E 11 LCD

Page 1: ...ACE Elektronisch geregelter Komfort Durchlauferhitzer Electronically controlled comfort instantaneous water heater Chauffe eau instantan confort r gulation lectronique Elektronisch geregelde comfort d...

Page 2: ...2 Appliance shutdown 36 13 Alternative installation methods 36 13 1 Electrical connection from above on unfinished walls 36 13 2 Electrical connection on unfinished walls with short power cable 36 13...

Page 3: ...for shower opera tion the qualified contractor must adjust the temperature setting range to 55 C or less using the internal anti scalding protection on the appliance When using preheated water it must...

Page 4: ...al losses appliance damage consequential losses and environmen tal pollution Appliance disposal f This symbol indicates that you have to do something The ac tion you need to take is described step by...

Page 5: ...ically controlled instantaneous water heater with au tomatic output matching maintains a consistent outlet tempera ture It is irrespective of the inlet temperature up to the maximum output of the appl...

Page 6: ...ng the following steps f Disconnect the appliance from the power supply by removing the fuses tripping the MCBs f Open the tap for one minute until the appliance and its upstream cold water inlet line...

Page 7: ...electrical resistance of the water must not fall below that stated on the type plate In a linked water net work factor in the lowest electrical resistance of the water Your water supply utility will...

Page 8: ...1 Cold water inlet 2 DHW outlet Oversink installation D0000057030 1 2 1 Cold water inlet 2 DHW outlet Note f Mount the appliance on the wall The wall must have sufficient load bearing capacity 9 2 Mi...

Page 9: ...ew Pivot open the appliance cover D0000053272 f Remove the back panel by pressing the two locking tabs and pulling the lower section of the back panel forwards Preparing the power cable on unfinished...

Page 10: ...the function module in the appliance back panel slightly towards the back f Remove the function module from the appliance back panel by pulling it slightly forwards and lifting it off D0000084719 4 5...

Page 11: ...t gaskets onto the water connections f Open the 3 way ball shut off valve or the shut off valve in the cold water supply line Making the electrical connection WARNING Electrocution Carry out all elect...

Page 12: ...ion Connected load DHB E 11 13 LCD Connected load DHB E 18 21 24 LCD 1 11 kW 18 kW 2 13 5 kW 21 kW 3 11 kW 24 kW No jumper 11 kW 18 kW 11 2 Initial start up 60 s D0000053277 f Open and close all conne...

Page 13: ...lls IP 24 Other IP rating Installation with offset tiles IP 25 Pivoting appliance cover IP 25 Horizontal installation of the appliance IP 24 WARNING Electrocution Before any work on the appliance disc...

Page 14: ...ng diagram 13 5 Water installation on finished walls Note This type of connection changes the IP rating of the ap pliance f Change the type plate Cross out IP 25 and mark the box IP 24 Use a ballpoint...

Page 15: ...ction can also be installed after fitting the taps valves To do this carry out the following steps f Cut open the lower section of the back panel f Fit the lower section of the back panel by bending i...

Page 16: ...This type of connection changes the IP rating of the appliance Cross out IP 25 on the type plate and mark the box IP 24 Use a ballpoint pen to do this Horizontal installation The appliance can also be...

Page 17: ...place if necessary Programming unit faulty Replacing the programming unit Faulty PCB Replacing the function module Green flashing yellow on red off No DHW outlet temperature does not match set value T...

Page 18: ...way ball shut off valve or the shut off valve in the cold water supply line before removing cleaning and refitting the strainer 17 Specification 17 1 Dimensions and connections 466 225 35 35 414 38 1...

Page 19: ...10 C 15 C 20 C DHB E 11 13 LCD 9 9 3 1 3 5 4 0 4 7 12 2 3 9 4 4 5 0 5 8 11 3 5 3 9 4 5 5 2 13 5 4 3 4 8 5 5 6 4 11 8 3 7 4 2 4 8 5 6 14 5 4 6 5 2 5 9 6 9 DHB E 18 LCD 25A 16 2 5 1 5 8 6 6 7 7 18 5 7...

Page 20: ...1 32 2 36 3 37 1 39 Fuses A 20 25 25 32 32 32 35 32 32 35 32 32 40 40 40 Frequency Hz 50 60 50 60 50 50 60 50 60 50 50 60 50 60 50 50 50 Phases 3 PE 3 PE 3 PE 3 PE Specific resistance 15 cm 900 900 9...

Page 21: ...can only be issued by those subsidiaries Such guarantee is only grant ed if the subsidiary has issued its own terms of guarantee No other guarantee will be granted We shall not provide any guarantee f...

Reviews: