STIEBEL ELTRON DEL 13 Plus AU Operation And Installation Download Page 7

iNSTALLATiON 

 

Safety

EN

GL

ISH

www.stiebel-eltron.com 

DEL Plus AU | 

7

 

Note

After a power failure 

Programming unit displays and selected settings are re-

tained following a power failure.

If you cannot remedy the fault, contact your qualified contractor. 

To facilitate and speed up your request, provide the number from 

the type plate (000000-0000-000000).

Nr. 000000-0000-00000

Nr. 000000-0000-00000

D

00000

53

31

2

iNSTALLATiON

7.  Safety

Only a qualified contractor should carry out installation, commis-

sioning, maintenance and repair of the appliance.

7.1  General safety instructions

We guarantee trouble-free function and operational reliability only 

if original accessories and spare parts intended for the appliance 

are used.

!

 

Material losses

Observe the maximum inlet temperature. Higher tem-

peratures may damage the appliance.  You can limit 

the maximum inlet temperature by installing a central 

thermostatic valve (see chapter "Appliance description / 

Accessories").

 

CAUTION Burns

If the water supplied to the appliance is preheated, 

please note the following points:

 

-

The internally adjustable anti-scalding protection 

and the temperature limit that is adjustable by the 

user may be exceeded.

 

-

The dynamic anti-scalding protection between the 

appliance and the wireless remote control may not 

be effective.

f

f

In both cases, limit the temperature with an up-

stream central thermostatic valve.

 

WARNING Electrocution

This appliance contains capacitors which are discharged 

when disconnected from the power supply. The capacitor 

discharge voltage may briefly reach > 60 V DC.

7.2  Instructions, standards and regulations

 

Note

Observe all applicable national and regional regulations 

and instructions.

 

- The IP 25 (hoseproof) rating can only be ensured with a cor-

rectly fitted cable grommet.

 

- The specific electrical resistivity of the water must not fall 

below that stated on the type plate. In a linked water net-

work, factor in the lowest electrical resistivity of the water. 

Your water supply utility will advise you of the specific elec-

trical water resistivity or conductivity.

Summary of Contents for DEL 13 Plus AU

Page 1: ...OPERATION AND INSTALLATION Electronically controlled comfort instantaneous water heater DEL 13 Plus AU DEL 18 Plus AU DEL 27 Plus AU Tmax T...

Page 2: ...8 1 Standard delivery 8 8 2 Accessories 8 9 Preparation 8 9 1 Installation location 8 9 2 Minimum clearances 8 9 3 Water installation 8 10 Installation 9 10 1 Standard installation 9 11 Commissioning...

Page 3: ...the appliance as described in chapter Installation Installation Observe the maximum permissible pressure see chapter Installation Specification Data table The specific water resistivity of the mains...

Page 4: ...with the appliance Children must never clean the ap pliance or perform user maintenance unless they are supervised Where children or persons with limited physical sensory or men tal abilities are all...

Page 5: ...t is enabled 4 3 Setting the temperature Tmax T D0000073010 2 1 1 Set temperature selector no end stop OFF 20 50 C factory setting 2 Call up assign preferred temperatures Setting steps Temperature ran...

Page 6: ...ks Internal anti scalding protection qualified contractors If required the qualified contractor can set a permanent temper ature limit for example in nurseries hospitals etc Recommended setting for op...

Page 7: ...e description Accessories CAUTION Burns If the water supplied to the appliance is preheated please note the following points The internally adjustable anti scalding protection and the temperature limi...

Page 8: ...sink installation D0000057030 1 2 1 Cold water inlet 2 DHW outlet Note f f Mount the appliance on the wall The wall must have sufficient load bearing capacity 9 2 Minimum clearances 50 50 90 90 D00000...

Page 9: ...e on unfinished walls for connection from below 160 30 D0000053273 1 1 Cable entry installation aid f f Prepare the power cable Fitting the wall mounting bracket D0000059694 f f Mark out the holes for...

Page 10: ...nd the DHW outlet pipe from the pipework with flat gaskets to the extensions from the appliance Making the electrical connection WARNING Electrocution Carry out all electrical connection and installat...

Page 11: ...installation the appliance cover should be turned round for easier operation see chapter Alter native installation methods Pivoting appliance cover Fit the appliance cover D0000040777 1 2 3 4 1 Pipe...

Page 12: ...IP 25 On unfinished walls connected from below short power cable IP 25 On finished walls IP 24 Water connection IP rating On unfinished walls IP 25 Other IP rating Installation with offset tiles IP 25...

Page 13: ...with a file f f Route the power cable through the cable grommet f f Connect the power cable to the mains terminal Note If the appliance is rated IP 24 amend the appliance type plate f f Cross out IP 2...

Page 14: ...y pressing the locking hooks and removing the programming unit f f Turn the appliance cover not the appliance the other way up and refit the programming unit Push the programming unit home in parallel...

Page 15: ...he PCB The flow meter is faulty Replace the flow meter The electronic assembly is faulty Replace the test assembly Green flashing yellow on red off The display is completely off Loose set value transd...

Page 16: ...in the threaded cold water fitting Close the shut off valve in the cold water inlet line before removing cleaning and refitting the strainer D0000077740 2 1 1 Strainer 2 Plastic profile washer f f Re...

Page 17: ...min Rated voltage Cold water inlet temperature 380 V 400 V 415 V 5 C 10 C 15 C 20 C DEL 13 Plus AU 12 2 3 8 4 3 4 9 5 7 13 5 4 3 4 8 5 5 6 4 14 5 4 6 5 2 5 9 6 9 DEL 18 Plus AU 16 2 5 1 5 8 6 6 7 7 1...

Page 18: ...Pa 1 1 1 Max inlet temperature for reheating C 50 50 50 Values Max permissible inlet temperature C 50 50 50 ON l min 2 5 2 5 2 5 Flow rate at 28 K l min 7 4 at 415V 9 9 at 415V 14 3 at 415V Flow rate...

Page 19: ...unit was not installed and commissioned a in Australia b in accordance with the Operating and Installation Guide and c in accordance with the relevant statutory and local require ments of the State or...

Page 20: ...ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 Fax 0387...

Reviews: