4
that holes
B
are aligned with the marks on the
wall you have just made. Now mark the upper
holes through holes
C
and
D
in the wall
mounting (
ΙΙ
). Drill the four holes, insert plugs
and screw the wall mounting securely to the wall
using four screws.
2.2Wall mounting the convector
On the backside of the convector there are 4
slots, these should be hooked onto the wall
bracket and pushed down.The spring clips
should be turned clockwise to secure. To remove
the convector reverse the above operation.
2.3 Installation with feet
Unhook the wall mounting bracket.
Remove the two screws from the bottom
of the appliance.Fit the feet to the bottom
of the appliance in such a way that they are
inserted into the recess at the back of the
appliance
。
Secure the feet with the screws
you just removed.
2.4 Electrical connection
This heater is for 220V AC.
Please observe national standards, the regula-
tions of your local electricity supply company as
well as data the rating label.
Electrical safety!
The convector heaters have protective system II
( ) and are spray protected ( IP24 ).
Note the details on the rating plate!
The voltage supply must match the require-
ments on the rating plate.The supply cable must
be correctly sized.The heater must be connected
to a socket outlet or permanent terminal box at
least 10 cm to one side of the heater. Any visible
damage of the electrical connections must be
rectified by a qualified electrician!
Please note in general:
Where the convector heater is fitted in a room
with a bath or shower, ensure the safety zone
defined in IEE Regulations is applied in
accordance with the details on the rating plate.
The unit is to be fitted in such a way that switch-
ing and control devices cannot be touched by
anyone in the bath or under the shower.
If the supply code is damaged, it must be repla-
ced by Stiebel Eltron company or its authorized
installer in order to avoid a hazard.
Do not use this heater with a programmer, timer
or any other device that switches the heater on
automatically,since a fire risk exits if the heater is
covered or positioned incorrectly.
Do not use this heater with feets in the immediate
surroundings of a bath, a shower or a swimming pool.