10.4 Power supply
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
!
Material losses
The specified voltage must match the mains voltage.
f
Observe the type plate.
The appliance is supplied fully wired (with a mains plug), but it is
also suitable for permanent connection.
10.4.1 Connection to a socket
!
Material losses
The power cable must not hang in front of the air dis-
charge.
f
Wind up any surplus power cable and stow it in the
cable compartment at the back of the appliance.
D
00000
56
91
0
1
1 Cable compartment
f
Insert the power plug of the appliance into a suitable socket.
10.4.2 Permanent connection
WARNING Electrocution
In the case of a permanent connection, the appliance
must be able to be separated from the power supply by
an isolator that disconnects all poles with at least 3 mm
contact separation.
!
Material losses
f
Trim the power cable so it leads directly to the appli-
ance connection socket.
f
Ensure that, after trimming the power cable, the
appliance can still be removed from the wall without
problem.
!
Material losses
This appliance is unsuitable for fixed electrical cables.
f
Trim the power cable by cutting off the plug.
f
Connect the power cable to a suitable socket.
11. Maintenance
!
Material losses
The power cable may only be replaced (for example if
damaged) by a qualified contractor authorised by the
manufacturer, using an original spare part.
12. Specification
12.1 Dimensions and connections
274
400
131
202
365
377
g01
g02
D
00000
56
44
9
CK 20 Trend
g01 Air intake
g02 Air discharge
12.2 Data table
CK 20 Trend
234918
Electrical data
Connected load
W
2000
Power supply
1/N ~ 230 V
Voltage range
V
220 - 240
Rated current
A
8.7
Frequency
Hz
50/-
Dimensions
Height
mm
400
Width
mm
275
Depth
mm
131
Weights
Weight
kg
2.50
Versions
Version
Wall mounted unit
Frost protection setting
°C
7
IP rating
IP 24
Protection class
II
Colour
Alpine white
Values
Output stages
1
Setting range
°C
7-35
Operating noise
dB(A)
49