INSTALLATION
Appliance handover
www.stiebel-eltron-usa.com
CK 150-1 / 200-2 Trend |
7
EN
GL
ISH
11.3.1 Permanent connection
WARNING:
Electrocution
The appliance must be able to be separated from the
power supply by an isolator that disconnects all poles.
!
MATERIAL LOSSES:
The appliance is suitable only for permanent connec-
tion.
f
Connect the permanent power supply cable to terminal block.
Never install the appliance directly below an outlet.
In case of ROMEX wire, install ½" ROMEX connector in knockout.
In case of Greenfield, please use ½" Greenfield connector.
11.4 Terminal
block
You must use copper wire for the terminal block connection.
We recommend using stranded wire to connect to the terminal
block. Crimp a ferrule over stranded bare wire to ensure a good
connection.
Consult the chart below for the recommended torque amounts on
the terminal block screws.
Screw Diameter (mm)
Torque (N•cm) Torque (lbf•in)
2.8
30-40
2.65-3.54
2.8-3
35-50
3.09-4.42
3-3.2
50-60
4.42-5.31
3.2-3.6
60-80
5.31-7.08
3.6-4.1
90-120
7.96-10.62
4.1-4.7
120-180
10.62-15.93
4.7-5.3
150-200
13.27-17.7
Using the proper torque specifications to secure wire to the wiring
block helps to avoid personal loss or property damage.
See 14.3, “Data table”, pg. 9 for information on the proper
wire gauge size.
12. Appliance handover
Explain the functions of the appliance to the user. Draw special
attention to the safety information. Hand the operating and in-
stallation instructions to the user.
13. Maintenance
!
MATERIAL LOSSES:
The spare parts may only be replaced (for example if
damaged) by a qualified contractor, using an original
Stiebel Eltron spare part.