16
| UFP 5 h www.stiebel-eltron.com
INSTALLATION
Commissioning
D
00000
42
20
7
9.2 Water connection
!
Material losses
Carry out all water connection and installation work in
accordance with regulations.
!
Material losses
Counterhold with a suitable spanner when tightening
fittings.
D
00000
42
20
6
!
Material losses
The appliance may develop a leak and cease functioning.
f
f
Never subject the appliance to water pressure.
f
f
Never interchange the water connections.
f
f
Set the flow rate (see tap instructions). Observe the
maximum permissible flow rate with a fully opened
tap (see chapter "Installation / Specification / Data
table").
Note
The levers for the twin-lever mixer tap for oversink in-
stallation are delivered DIN 44897-compliant:
- Cold water on the left (blue)
- Hot water on the right (red)
f
f
Secure the water connections from the tap to the appliance.
9.3 Power supply
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
When permanently connected to the power supply using
a dedicated junction box, the appliance must be able to
be isolated from the mains power supply by an isolator
that disconnects all poles with at least 3 mm contact
separation.
WARNING Electrocution
Ensure that the appliance is earthed.
!
Material losses
The voltage specified on the type plate must match the
mains voltage.
f
f
Observe the type plate.
The following electrical connections are permissible:
UFP 5 h UFP 5 h LABS
Connection to a freely accessible standard sock-
et with matching plug
X
X
Permanent connection to an appliance junction
box with earth conductor
X
X
10. Commissioning
WARNING Electrocution
Commissioning may only be carried out by a qualified
contractor in accordance with safety regulations.
10.1 Initial start-up
1.
2.
D
00000
49
32
5
f
f
Either open the DHW valve of the tap or set the mono lever
mixer tap to "hot" until the water that flows out is free of air
bubbles.
f
f
Insert the plug into the standard socket or set the fuse/MCB
in the fuse box.
f
f
Select a temperature.
f
f
Check the entire hydraulic installation for tightness.
Note
If you fail to follow the correct sequence (first water, then
power), the high limit safety cut-out will trip.
Proceed as follows:
f
f
Disconnect the appliance from the power supply.
f
f
Fill the appliance with water.
f
f
Connect the appliance to the power supply.