STIEBEL ELTRON 201683 Operation And Installation Download Page 28

Deutschland

STIEBEL ELTRON GmbH & Co. KG
Dr.-Stiebel-Straße 33 | 37603 Holzminden
Tel. 05531 702-0 | Fax 05531 702-480
[email protected]
www.stiebel-eltron.de

Verkauf   

Tel. 05531 702-110 | Fax 05531 702-95108 | [email protected]

Kundendienst 

Tel. 05531 702-111 | Fax 05531 702-95890 | [email protected]

Ersatzteilverkauf 

Tel. 05531 702-120 | Fax 05531 702-95335 | [email protected]

Irrtum und technische Änderungen vorbehalten! | Subject to errors and technical changes! | Sous réserve d‘erreurs 
et de modifications techniques! | Onder voorbehoud van vergissingen en technische wijzigingen! | Salvo error o 
modificación técnica! | Excepto erro ou alteração técnica | Zastrzeżone zmiany techniczne i ewentualne błędy | Omyly a 
technické změny jsou vyhrazeny! | A muszaki változtatások és tévedések jogát fenntartjuk! | 

Отсутствие ошибок не 

гарантируется. Возможны технические изменения

. | Chyby a technické zmeny sú vyhradené!  Stand  9442

Australia

STIEBEL ELTRON Australia Pty. Ltd.

294 Salmon Street | Port Melbourne 

VIC 3207

Tel. 03 9645-1833 | Fax 03 9645-4366

[email protected]

www.stiebel.com.au

Austria

STIEBEL ELTRON Ges.m.b.H.

Gewerbegebiet Neubau-Nord

Margaritenstraße 4 A | 4063 Hörsching

Tel. 07221 74600-0 | Fax 07221 74600-42

[email protected]

www.stiebel-eltron.at

Belgium

STIEBEL ELTRON bvba/sprl

't Hofveld 6 - D1 | 1702 Groot-Bijgaarden

Tel. 02 42322-22 | Fax 02 42322-12

[email protected]

www.stiebel-eltron.be

China

STIEBEL ELTRON (Tianjin) Electric 

Appliance Co., Ltd.

Plant C3, XEDA International Industry City

Xiqing Economic Development Area

300085 Tianjin

Tel. 022 8396 2077 | Fax 022 8396 2075

[email protected]

www.stiebeleltron.cn

Czech Republic

STIEBEL ELTRON spol. s r.o.

K Hájům 946 | 155 00 Praha 5 - Stodůlky

Tel. 251116-111 | Fax 235512-122

[email protected]

www.stiebel-eltron.cz

Finland

STIEBEL ELTRON OY

Kapinakuja 1 | 04600 Mäntsälä

Tel. 020 720-9988

[email protected]

www.stiebel-eltron.fi

France

STIEBEL ELTRON SAS

7-9, rue des Selliers

B.P 85107 | 57073 Metz-Cédex 3

Tel. 0387 7438-88 | Fax 0387 7468-26

[email protected]

www.stiebel-eltron.fr

Hungary

STIEBEL ELTRON Kft.

Gyár u. 2 | 2040 Budaörs

Tel. 01 250-6055 | Fax 01 368-8097

[email protected]

www.stiebel-eltron.hu

Japan

NIHON STIEBEL Co. Ltd.

Kowa Kawasaki Nishiguchi Building 8F

66-2 Horikawa-Cho

Saiwai-Ku | 212-0013 Kawasaki

Tel. 044 540-3200 | Fax 044 540-3210

[email protected]

www.nihonstiebel.co.jp

Netherlands

STIEBEL ELTRON Nederland B.V.

Daviottenweg 36 | 

5222 BH 's-Hertogenbosch

Tel. 073 623-0000 | Fax 073 623-1141

[email protected]

www.stiebel-eltron.nl

Poland

STIEBEL ELTRON Polska Sp. z O.O.

ul. Działkowa 2 | 02-234 Warszawa

Tel. 022 60920-30 | Fax 022 60920-29

[email protected]

www.stiebel-eltron.pl

Russia

STIEBEL ELTRON LLC RUSSIA

Urzhumskaya street 4,

building 2 | 129343 Moscow

Tel. 0495 7753889 | Fax 0495 7753887

[email protected]

www.stiebel-eltron.ru

Slovakia

TATRAMAT - ohrievače vody s.r.o.

Hlavná 1 | 058 01 Poprad

Tel. 052 7127-125 | Fax 052 7127-148

[email protected]

www.stiebel-eltron.sk

Switzerland

STIEBEL ELTRON AG

Industrie West

Gass 8 | 5242 Lupfig

Tel. 056 4640-500 | Fax 056 4640-501

[email protected]

www.stiebel-eltron.ch

Thailand

STIEBEL ELTRON Asia Ltd. 

469 Moo 2 Tambol Klong-Jik

Amphur Bangpa-In | 13160 Ayutthaya

Tel. 035 220088 | Fax 035 221188

[email protected]

www.stiebeleltronasia.com

United Kingdom and Ireland

STIEBEL ELTRON UK Ltd.

Unit 12 Stadium Court

Stadium Road | CH62 3RP Bromborough

Tel. 0151 346-2300 | Fax 0151 334-2913

[email protected]

www.stiebel-eltron.co.uk

United States of America

STIEBEL ELTRON, Inc.

17 West Street | 01088 West Hatfield MA

Tel. 0413 247-3380 | Fax 0413 247-3369

[email protected]

www.stiebel-eltron-usa.com

A 339843-41288-9452

B 340392-41288-9452 

4<AMHCMO=djiedb>

Summary of Contents for 201683

Page 1: ...Electronically controlled mini instantaneous water heater DEM 6 AU OPERATION AND INSTALLATION...

Page 2: ...cription 9 8 1 Standard delivery 9 8 2 Accessories 10 9 Preparation 10 10 Installation 10 10 1 Installation site 10 10 2 Alternative installation methods 11 10 3 Making the electrical connection 14 11...

Page 3: ...in excess of 43 C Ensure the appliance can be separated from the power supply by an isolator that disconnects all poles with at least 3 mm contact separation The specified voltage must match the main...

Page 4: ...equired 1 1 Safety instructions 1 1 1 Structure of safety instructions KEYWORD Type of risk Here possible consequences are listed that may result from failure to observe the safety instructions f f St...

Page 5: ...nt Note All measurements are given in mm unless stated oth erwise 2 Safety 2 1 Intended use This appliance is suitable for heating domestic hot water or for reheating preheated water The appliance is...

Page 6: ...Children must never play with the appliance Cleaning and user maintenance must not be carried out by children without supervision WARNING For continued safety of this appliance it must be in stalled o...

Page 7: ...stem has a low susceptibility to scale build up The heating system ensures quick and efficient DHW provision at the hand washbasin Your qualified contractor can adjust the maximum temperature and flow...

Page 8: ...The water supply has been interrupted Vent the appliance and the cold water inlet line see chapter Settings The required tempera ture is not being reached The maximum tempera ture set inside the appl...

Page 9: ...om the power supply The capacitor discharge voltage may briefly reach 34 V DC 7 2 Instructions standards and regulations Note Observe all applicable national and regional regulations and instructions...

Page 10: ...nstall the appliance in a room free from the risk of frost and near the draw off tap Ensure that the lateral fixing screws for the cover are always ac cessible The appliance is suitable for undersink...

Page 11: ...ltron com DEM AU 11 Installation Installation 10 2 Alternative installation methods 10 2 1 Undersink installation Pressure tested with pressure tested tap D0000086682 Non pressurised with non pressuri...

Page 12: ...screws by two turns f f Undo the snap fastener using a screwdriver f f Remove the appliance cover with the heater towards the front f f Using pliers break out the knock out for the power cable in the...

Page 13: ...ducers supplied incl flat gaskets onto the ap pliance water connections Tap installation Material losses f f When making the connections counter the torque on the appliance using a size 14 spanner Pre...

Page 14: ...lectrocution Carry out all electrical connection and installation work in accordance with relevant regulations DANGER Electrocution Ensure that the appliance is earthed Ensure the appliance can be sep...

Page 15: ...case of oversink installation affix the company logo supplied over the existing company logo 11 2 Appliance handover f f Explain the appliance function to users and familiarise them with how it works...

Page 16: ...ture may only be adjusted if the appliance is isolated from the power supply f f Isolate all poles of the appliance from the power supply DANGER Electrocution The adjusting screw for changing the flow...

Page 17: ...ver set the potentiometer to the maximum required temperature f f Fit the appliance cover Limiting the flow rate Factory setting Maximum flow rate 26_02_05_0079_ f f Using the adjusting screw set the...

Page 18: ...ne is blocked Clean the sieve after shutting off the cold water inlet line The heating system is faulty Check the resistance of the heating system and replace the appliance if required The safety pres...

Page 19: ...appliance discon nect all poles from the power supply 14 1 Draining the appliance DANGER Scalding Hot water may escape when you drain the appliance If the appliance needs to be drained for maintenanc...

Page 20: ...t as water residues remaining inside the appliance can freeze and cause damage 14 4 Replacing the power cable f f If making a replacement use a 4 mm connecting cable 15 Specification 15 1 Dimensions a...

Page 21: ...rmanent power supply connect the power cable according to the designations on the socket terminals 15 3 Temperature increase The water increases in temperature as follows at a voltage of 230 V 25 0 27...

Page 22: ...ecific electrical con ductivity see Installation Data table Standard specifica tion at 15 C 20 C 25 C Spec Re sistivity Spec Conduc tivity Spec Re sistivity Spec Conduc tivity Spec Re sistivity Spec C...

Page 23: ...ity 15 at cold 25 C S cm 1000 Specific resistance 15 at cold 50 C cm 1300 Specific conductivity 15 at cold 50 C S cm 770 Max mains impedance at 50 Hz 0 056 0 051 0 049 0 047 Connections Water connecti...

Page 24: ...forms to IEC 61000 3 12 Guarantee The guarantee conditions of our German companies do not apply to appliances acquired outside of Germany In countries where our subsidiaries sell our products a guaran...

Page 25: ...he Operating and Installation Guide 12 4 The unit does not bear its original Serial Number for Rating Label 12 5 The unit was damaged by any or any combination of the follow ing a normal fair wear and...

Page 26: ...ans that the unit is used in a domestic dwelling Component Warranty period All components 5 years from the date of completion of the installation of the unit 7 The warranty period for a unit used for...

Page 27: ...ide safe and free access to it at your cost 16 If we reject your warranty claim in accordance with clause 12 we may charge you for our authorised service technician s labour costs to inspect and test...

Page 28: ...OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 Fax 0387 7468...

Reviews: