EN
GL
ISH
WWW.STIEBEL-ELTRON.COM
BGC |
13
INSTALLATION
MOUNTING
BGC | BGC/45
≤ 65
1
26
�0
2�
79
�0
04
4
BGC 2 | BGC 2/60
≤ 100
1
26
�02
�7
9�
00
75
1 Extension (BGC/45 | BGC 2/60)
f
f
If you install the appliance in a cylinder with thermal insula-
tion, use a threaded immersion heater with extension. You
can also use the extension to reduce the immersion depth
(see chapter “Specification / Data table”). The maximum
clearance between the threaded immersion heater and cylin-
der (see diagram) must not be exceeded.
Connecting the power supply
WARNUNG Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNUNG Electrocution
Make the power supply only as a permanent connection.
The appliance must be able to be separated from the
mains power supply by an isolator that disconnects all
poles with at least 3 mm contact separation.
!
Geräte- und Umweltschäden
Observe the type plate. The specified voltage must match
the mains voltage.
Hinweis
Ensure that the appliance is earthed.
f
f
Pull off the temperature selector.
f
f
Undo the screws.
f
f
Remove the cap.
100
200
26
�0
2�
79
�0
04
9
f
f
Prepare the power cable, ensuring that the earth conductor
is longer than the other conductors.
f
f
Feed the power cable through the cable entry into the control
panel.
f
f
Connect the required load in accordance with the connection
examples (see chapter “Specification / Wiring diagrams and
connections”).
f
f
Tick the selected connected load and voltage on the type
plate. Please use a ballpoint pen to do this.
f
f
Affix the relevant wiring diagram label if required over the
wiring diagram in the cap.
Completing the installation process
f
f
Replace the cap and secure it with screws.
f
f
Replace the temperature selector.