© STid
–
MU_SWEDGE_V1.11_EN
11
3.
Reader Configuration
If the reader was not purchased in a kit SWEDGE, it is necessary to configure it to work with the
software.
STR-R35-B/x03-5X and STR-R32-B/x03-5X
These readers require no special configuration before use with SWEDGE. The reader reads the chip
serial number in hexadecimal and sends it to SWEDGE on UID tag format.
STR-W15-A/E01-5G and STR-W12-A/E01-5G
The factory default parameters of these readers are read/write. To work with SWEDGE, they must
be set to standalone. To do this, commands must be sent using a HyperTerminal.
Operating procedure:
•
Open an Hyperterminal
•
Connect the reader to configure
•
Set the communication port:
o
Port COM number
o
Baudrate 9600 bds
o
Bits: 8
o
Stop Bit 1
o
Parity: none
•
Send the three commands (hexadecimal value):
o
\02\20\04\00\00\24\03
reader answer: \02\20\00\00\20\03
o
\02\2E\01\00\00\2F\03
reader answer: \02\2E\00\00\2E\03
o
\02\22\01\00\00\23\03
reader answer: none
•
Checking: present a 125 KHz card on the reader, it must read continuously (beeps).
The reader reads the chip serial number (EM410x default chip) in hexadecimal and sends it to
SWEDGE on a 40 bits frame (5 bytes).