Receiver Modes of Operation

Normal Operating Mode

When a sensor is activated, short beeps will sound just before the alert tone to identify the 
activated sensor (i.e. 1 beep = channel 1, 2 beeps = channel 2 etc.), then the red LED on the 
receiver will flash indicating which channel has been alerted (i.e. 1 flash = channel 1, 2 flashes =  
channel 2).  The green LED will flash periodically to indicate routine signals are being received.  
This does not mean a sensor has been activated.

If more than 2 sensors have been activated at the same time, the receiver will only give short 
beeps for two activated sensors. The red LED will flash indicating all channels which have been 
activated. Once the sensor is restored to normal condition, to reset the red LED, press and 
release the receiver button. 

Temporary (8 Hours) and Permanent Silent Modes

These modes may be entered only while the receiver is in normal operating mode. If in 
permanent silent mode and there is a power outage, the receiver will stay in permanent silent 
mode until exited.  While in temporary or permanent silent mode, the red LED will change from 
continuous to flashing when a sensor has been activated.

Entering Temporary Silent Mode - 

Press and hold down

 the receiver button until you hear a 

single beep (approximately 3 seconds).  Red LED will be on solid.

Entering Permanent Silent Mode - 

Press and hold down

 the receiver button until the receiver 

makes a series of two short beeps (approximately 6 seconds).  Red LED will be on solid.

Exit both Silent Modes - 

Press and hold down

 the receiver button until you hear a single beep 

to return to normal operating mode (approximately 3 seconds). Red LED will go off.

Clearing the Receiver memory

1. 

Disconnect power from receiver

 and wait approximately 15 seconds.  

2. 

Reconnect power to the receiver,

 the receiver will make a start-up tone. The green LED 

will be solid.   

3. 

Within 3 seconds press and hold down the receiver button

, you will hear a series 

of beeps/tones. When you hear a continuous tone, let go of the button; the sensors are 
cleared.

Notes

•  Test a sensor by activating the sensor (refer to Sensor Instructions).  The receiver should 

beep once, twice, etc. then make the alert tone.  If your receiver does not respond correctly 
see trouble shooting tips.

•  Additional sensors can be programmed without clearing receiver memory using “Program 

a Sensor” instructions.

•  At least 5 seconds is needed after activation before pushing the receiver button for any 

function.  

•  Programmed sensors will remain in memory, unless clearing procedure is followed (even if 

power is lost).

•  Sensor alert status will be lost if receiver loses power.

Summary of Contents for STI-34104

Page 1: ...OR MORE PLACE SENSOR TRANSMITTER 3 OR LESS FROM EDGE OF DRIVEWAY AND 25 OR MORE FROM STREET 12 MAX POWER CONNECTOR ANTENNA CONNECTOR 4 Channel Receiver STI 34104 Receives up to 4 different STI Wireless Alert Series Sensors Program a Sensor 1 Plug antenna into the antenna red connector on the receiver 2 Plug adapter into the wall 3 While holding down the receiver button plug the adapter into the 4 ...

Page 2: ... down the receiver button until you hear a single beep approximately 3 seconds Red LED will be on solid Entering Permanent Silent Mode Press and hold down the receiver button until the receiver makes a series of two short beeps approximately 6 seconds Red LED will be on solid Exit both Silent Modes Press and hold down the receiver button until you hear a single beep to return to normal operating m...

Page 3: ...k the AC power outlet for power 2 Check that the AC Adapter is plugged into both the receiver and wall outlet 3 Try another AC adapter 12V DC 100mA only with a 12 VDC center and 12 VDC outside edge The receiver does not sound when a sensor is activated 1 Check that the receiver is not in Temporary or Permanent Silent Mode 2 Move the sensor close to the receiver and test If alert sounds on the rece...

Page 4: ...eas To prevent electric shock match wide blade of plug to the wide slot of outlet and insert completely When using lamp controller option use ONLY 200 Watt or less incandescent lamps and keep lamp away from bed coverings curtains or other flammable materials as this may present a fire hazard Warranty Information Safety Technology International Inc warrants to the original consumer purchaser that t...

Reviews: