Operating instructions (Version 0)
34
ST 1075
5.2
Control box
All functions of the lifting system are controlled from the control box on the column
lift (see
).
Note
n
Operate the panel only with your fingertips. Pressing the buttons using sharp objects
(such as screwdrivers) can damage the equipment and cause errors.
5.2.1 Emergency shutdown button
If the emergency shutdown switch is pressed, all movements are immediately halted
(raising or lowering).
5.2.2 Starting and identification
Each of the columns has a main switch. This switch has two positions:
0 (OFF)
This interrupts the power supply to the column lift.
1 (ON)
This switches on the power supply to the column lift.
Figure 5.2
Control box
1. Emergency stop button
2. Information screen
3. UP button
4. DOWN button
5. <SELECT> button
6. UNLOCK button
7. Slow lowering selection
button
8. <FAULT> indicator
9. <ALL> indicator
10. <SINGLE> indicator
11. <PAIR> indicator
12. ID key reader
(antenna)
13. ID key
14.Interconnection cables