14
SETTINGS ADJUSTMENT
DETECTION RANGE:
Only if necessary, use the remote control
to adjust the sensor range as follows:
Press the RANGE button. Wait until a quick flashing of the red light
of the sensor eye is perceived. Then, press + to increase the one
level and – to reduce it every push will increase or decrease
one level.
Note:
Once you have changed the detection range with the remote control,
this distance will be remembered by the sensor, even if the power source is
disconnected.
SECURITY TIME:
The Security time, prevents continuous running
of water due to reflections or vandalism. By default, if the sensor
is covered for more than 90 seconds the water flow will shut
automatically. To resume regular operation any obstruction must
be removed.
Press the SEC button. Wait until a quick flashing of the red light of
the sensor eye is perceived. Then, press + to increase the security
time and – to reduce it.
DELAY IN TIME:
It is recommended to change the delay in time for
flush valves for urinals or toilets only.
If required, the delay in time can also be modified in faucets as
follows:
Press the IN button. Wait until a quick flashing of the red light of
the sensor eye is perceived. Then, press + to increase the delay in
time and – to reduce it.
DELAY OUT TIME:
This button allows modifying the water flow
time after the user removes his hands from the faucet. A delay out
time close to 0 will save more water. An increased delay out time
will make the user experience more comfortable.
If required, the delay out time can be modified as follows:
Press the OUT button. Wait until a quick flashing of the red light of
the sensor eye is perceived. Then, press + to increase the delay
out time and – to reduce it.