Stern Extreme 1000 B 237100 Installation And Maintenance Manual Download Page 10

16

TrouBlEshooTINg

* “Security mode”: If the sensor is covered for more than 90 sec. the faucet will automatically shut off water flow. 

To return to normal operation remove any blockage.
** In this case, the water flow will stop anyway after 90 seconds because of the security time.

soluTIoN

causE

 INDIcaTor

 ProBlEm

Replace battery

Low battery.

1. Sensor flashes 

continuously 

when user’s 

hands are within 

the sensor’s 

range.

No water 

coming out 

of the faucet:

Increase the range

1. Range is too short.

2. LED in the 

sensor does not 

flash once when 

user’s hands   

are within the 

sensor’s range.

Decrease the range

2. Range is too long.

The battery must be replaced. 

3. Battery is completely used up 
4. Unit is in “Security mode”*

Eliminate cause of reflection. 

5. Sensor is picking up reflections from the 

washbasin or another object.

Connect the electronic unit 

connectors to the solenoid.

1. Connectors between the electronic unit and 

solenoid are disconnected.

3.LED in the 

sensor flashes 

once when 

user’s hands 

are within the 

sensor’s range.

Unscrew solenoid, pull out the 

plunger and the spring from 

the solenoid and clean them. 

Use scale remover material if 

needed. When replacing the 

plunger, please make sure that 

the spring is in vertical position. 

2. Debris or scale in solenoid.

Clean the orifice or replace 

diaphragm. 

3. The central orifice in the diaphragm is 

plugged or the diaphragm is torn

Reduce the supply water 

pressure.

4. The water supply pressure is higher than 8 

bar.

Shut off water supply and 

unscrew one of the flexible 

pipes in order to reduce the 

pressure that blocks the 

product.

5. The water supply pressure is under 8 bars 

and yet the pressure in the faucet’s body is 

higher. This situation could be caused by a 

sudden increase in the water supply pressure 

that the back check prevents from dropping, 

even after water supply pressure drops under 

8 bars.

Clean the orifice or replace 

diaphragm. 

1. Debris or scale in diaphragm

1. Sensor flashes 

once when 

user’s hands 

are within the 

sensor’s range. 

Water flow 

from spout 

does not 

stop:

Clean or eliminate case of 

interference.

1. Sensor is dirty or covered.**

2.LED in the 

sensor does not 

flash once when 

user’s hands 

are within the 

sensor’s range.

Decrease the range or eliminate 

cause of reflection. 

2. Sensor is picking up reflections from the 

washbasin or another object.

Remove, clean, re-install

Filter or aerator is clogged

Water flow 

diminished

Summary of Contents for Extreme 1000 B 237100

Page 1: ...1 I n sta l l at i o n a n d m a i n t e n a n c e g u i d e extreme SERIES ELECTRONIC LAVATORY FAUCET...

Page 2: ...anties of merchantability fitness for a particular purpose or non infringement Stern Engineering Ltd assumes no responsibility for errors or omissions in the information presented in this document In...

Page 3: ...ntents extreme 1000 Familiarize yourself with the part names and confirm that the parts are included 1 x Allen key 1 x Faucet and attachments TALL plus VERSIONs 2 x Filter 1 x Allen key TALL plus VERS...

Page 4: ...t to install your electronic faucet until you obtain the missing parts Warnings Do not install facing a mirror or any other electronic system operated by an infrared sensor To prevent reflection probl...

Page 5: ...and secure the faucet into its place installation installation Step 1 Preparation for mounting the faucet 1 Shut off the water supply 2 Remove the hexagonal nut the disk and the gasket Do not remove...

Page 6: ...ion must point down For Extreme HL Insert the 9V battery into the Dual Power Input Box battery compartment TRANSFORMER VERSION Plug the transformer into the electricity socket and connect the connecto...

Page 7: ...save more water An increased delay out time will make the user experience more comfortable If required the delay out time can be modified as follows Press the OUT button Wait until a quick flashing of...

Page 8: ...al Power Input Box 06530042 Remote control 13B 07100005 Soap Water Remote control 07100014 When the battery weakens the LED will blink at a constant rate The battery must be replaced within two weeks...

Page 9: ...Engineering Ltd will at its discretion repair provide a replacement part or product or make appropriate adjustments Damage caused by accident misuse or abuse is not covered by this warranty Improper c...

Page 10: ...d clean them Use scale remover material if needed When replacing the plunger please make sure that the spring is in vertical position 2 Debris or scale in solenoid Clean the orifice or replace diaphra...

Page 11: ...18 3 2018 015237100 c 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com...

Reviews: