OPeRaTiOn:
This faucet features an IP67 dual power input box. The product can be operated with a
9V battery or a 9V transformer. In addition, when used with a transformer, the product
contains an integrated battery back up, for normal use during power supply failures.
sTeP 1 - iNsTalliNg The fauceT
1.
Shut off the water supply
2.
Cut an adequate opening in the wall for the dimensions of the faucet base (where
you want to install the spout), and the corrugated tube.
3.
Install the D28 dual power base and its attachments through the opening
that was cut in the wall.
4. After you have connected the power source (battery or
transformer) wait 15 seconds in order to allow the system
to set the ideal sensor range. As an indication that the self
adjusting is taking place, a LED in the sensor eye will flash
continuously. The solenoid valve will be opened and closed
for 1 second as an indication that the ideal sensor range was
set and the product is ready for use.
5.
Assemble the temporary protective faucet base cover.
(See FIG.2)
6. Make sure the corrugated tube stays outside the wall when
tiling
.
7.
Once the works on electricity, plumbing and tiles is finished,
insert the wall rosette through the faucet base.
8. Cut the temporary faucet base cover.
9. Pull the four way connector out of the faucet base, and lead it
along with the flexible tube, through the corrugated tube.
10. Connect the flexible tube to the solenoid valve body
integrated in the dual power input box. (See FIG.3)
11. Connect the water tube coming from the faucet body to the
nut at the top of the dual power input box, by snapping it in.
12. Fix the faucet spout by inserting the nipple into the faucet
base and tighten the screw.
D28 Dual Power B
D28 Dual Power e
D28 Dual Power B
D28 Dual Power e
sTeP2 – coNNecTiNg The Power source
Check that no objects are in front of the
sensor besides the washbasin.
Now, remove the protective sticker that
covers the sensor.
1. If your model is D28 Dual Power B open the dual power box using the Allen key
provided and install the 9V Alkaline battery.
2. Connect the four contacts connector to the dual power input box.
important: Make sure that the 4 contacts connector is connected all the way through.
3. After you have connected the four contacts connector to the dual power input box,
wait 15 seconds in order to allow the system to set the ideal sensor range.
As an indication that the self adjusting has taken place, a LED in the sensor
eye will flash continuously. The solenoid valve will open and close for 1 second as
an indication that the ideal sensor range was set and the product is ready for use.
sTeP 3 – coNNecTiNg The waTer suPPly
1. Turn on the central water supply.
2. Check for leaks.
3. If the automatically adjusted sensor range is not satisfactory, please refer to the
section entitled “Settings adjustment”.
iNsTallaTioN