Stern Engineering SWAN 1000 AB1953 Installation And Maintenance Manual Download Page 8

12

13

Carefully push the sensor into the 

faucet’s body to gain access to the 

battery and pull it out of the body together 

with the battery. 
Replace the used battery with a new 9V 

battery. A lithium battery is recommended. 

Release the Allen screw to carefully 

remove the faucet’s body. 

Disconnect the connector from the elec-

tronic unit’s connector.   

If your model is Swan 1000

:

Release the handle-set-screw to 

remove the mixing handle. Release the 

Allen screw to carefully remove the axis 

assembly by pulling it out.

Turn off the shut off valve (angle valve). 

If your model is Swan 1010

, go to

1

2

When the battery weakens, the red indicator light will blink at a constant rate. The battery 

must be replaced within two weeks. 

BATTERy REPlAcEmENT

BATTERy REPlAcEmENT

To replace the battery at Swan 1010  \ Swan 1000 models:

3

4

Prior to reassembling the electronic unit and the battery, make sure that the o-ring is still 

in its groove and not damaged. Replace it with a new one if needed. Clean and lubricate 

it with silicone grease.

Important:

 Make sure that the faucet is not wet when reassembling the electronic unit.   

5

3

screw

connectors

Reconnect the electronic unit’s 

connector to the solenoid connector. 

Place the body, and tighten the screw.

If your model is Swan 1000:

Reassemble the axis-assembly and tighten 

the Allen screw. Reassemble the mixing 

handle and tighten the Allen screw.

Turn on the shut off valve (angle valve).

Carefully place the battery inside the 

body and reassemble the electronic 

unit in its place. be sure to insert the elec-

tronic unit all the way back into the opening 

in the faucet’s body by pushing it moder-

ately into the o-ring. 
Swing the sensor gently to align it with its 

location. be careful and make sure that you 

do not tear the o-ring. If torn replace it with 

a new one.

6

7

o-ring

electronic unit

screw

Summary of Contents for SWAN 1000 AB1953

Page 1: ...1 SWAN SERIES Installation and maintenance guide INSTALLATIE EN ONDERHOUDSGIDS ELECT RONIC LAVATORY FAUCET ELEKTRONISCHE FONTEINKRAAN SWAN SERIE swan 1010 AB1953 swan 1000 AB1953...

Page 2: ...um sensor range 80 mm Maximum sensor range 300 mm Security time 90 seconds Adjustable with remote control Hot water temperature Max 70 C swan 1010 ab1953 250220 swan 1000 ab1953 252210 swan 1010 b ab1...

Page 3: ...E AB1953 Pack contents Familiarize yourself with the part names and confirm that the parts are included 1 x Faucet and attachments 1 x Faucet and attachments 1 x Allen Key 1 x Allen Key E VERSIONS B...

Page 4: ...part with the Pack contents section Pay attention to the different models variations Make sure all parts are accounted for before discarding any packaging material If any parts are missing do not att...

Page 5: ...ting the power source 1 If your model is Swan 1010 Swan 1000 your product contains an internally mounted 9V battery To activate it proceed to clause 2 If your model is Swan 1010 B Swan 1000 B install...

Page 6: ...he one level and to reduce it every push will increase or decrease one level Note Once you have changed the detection range with the remote control this distance will be remembered by the sensor even...

Page 7: ...r hand to the required distance from the sensor and wait until the red light will stop flashing 7 When the red light has turned off the sensor has been adjusted to the required distance 8 Check the di...

Page 8: ...3 4 Prior to reassembling the electronic unit and the battery make sure that the o ring is still in its groove and not damaged Replace it with a new one if needed Clean and lubricate it with silicone...

Page 9: ...s should be protected from any splattering of harsh cleansers Seals and Screws Kit for Swan 1010 models 07210001 Seals and Screws Kit for Swan 1000 models 07210029 10 pack sensor kit for Swan 1010 Swa...

Page 10: ...uced by the water supply or soap tank Use of the soap outside of viscosity specifications Alteration of the original soap foam dispenser components including pipes SOLUTION CAUSE INDICATOR PROBLEM Rep...

Page 11: ...sorbereik 300 mm Beveiliging tijd 90 seconden Aanpasbaar met afstandsbediening Warmwater temperatuur Max 70 C swan 1010 ab1953 250220 swan 1000 ab1953 252210 swan 1010 b ab1953 250310 swan 1010 e ab19...

Page 12: ...B E AB1953 SWAN 1000 B E AB1953 Raak vertrouwd met de namen van de onderdelen en bevestig dat alle onderdelen meegeleverd zijn 1 x Kraan met toebehoren 1 x Kraan met toebehoren 1 x Inbussleutel 1 x In...

Page 13: ...at elk onderdeel overeenkomt met de sectie Inhoud van het pakket Let op de diverse variaties van de modellen Zorg dat alle onderdelen aanwezig zijn voordat u het verpakkingsmateriaal verwijdert Mochte...

Page 14: ...N VAN DE STROOMVOORZIENING 1 Als uw model Swan 1010 Swan 1000 is uw product bevat een intern gemonteerde 9V batterij Om deze te activeren ga verder naar item 2 Als uw model Swan 1010 B Swan 1000 B is...

Page 15: ...oten en op om het te verkleinen Elke keer dat u drukt wordt een afstand vergroot of verlaagd Opmerking Nadat u het detectiebereik met de afstandsbediening heeft veranderd wordt de afstand door de sens...

Page 16: ...de gewenste afstand van de sensor en wacht tot het rode lampje niet meer knippert 7 Wanneer het rode lampje is gedoofd is de sensor op de gewenste afstand ingesteld 8 Controleer de afstand die u hebt...

Page 17: ...leer dat voordat u de elektronische eenheid en de batterij opnieuw monteert de O ringniet beschadigd is en zich nog in zijn groef bevindt Indien nodig vervang deze met een nieuwe Reinigen en insmeren...

Page 18: ...oeten de kranen worden beschermd tegen spatten van harde reinigingsmiddelen Pakket met afsluitringen en schroeven voor Swan 1010 modellen 07210001 Pakket met afsluitringen en schroeven voor Swan 1000...

Page 19: ...al is de aansprakelijkheid van Stern Engineering Ltd hoger dan de aankoopprijs van het product Als u van mening bent dat u een claim op de garantie heeft neem dan contact op met uw Stern distributeur...

Page 20: ...36 08 17 01500339 A 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com...

Reviews: