Stern Engineering Green Time 1000 225810 Installation And Maintenance Manual Download Page 1

1

E L E C T R O N I C   L A V A T O R Y   F A U C E T

GREEN timE & GREEN timE 1000

InstallatIon and MaIntenance GuIde

Summary of Contents for Green Time 1000 225810

Page 1: ...1 E L E C T R O N I C L A V A T O R Y F A U C E T GREEN time GREEN time 1000 Installation and Maintenance Guide...

Page 2: ...ressure reducing valve Hot Water Supply Max 70 C Default flow time 8 seconds Programmable flow time 1 60 seconds 1 TECHNICAL DATA 2 3 PACK CONTENTS 4 PRE INSTALLATION INFORMATION 5 FAUCET INSTALLATION...

Page 3: ...1 Technical data Green Time 225910 Green Time 1000 225810 Green Time 1000 B 225880 Green Time 1000 E 225830 Green Time B 225910 Green Time E 225970...

Page 4: ...r 9V Battery box Transformer b VERSIONS e VERSIONS OPTIONAL IP67 Battery Box IP67 Transformer Box 1x Allen key Green time B E 1x Tap and attachments 1x Filter 1x Allen key Familiarize yourself with th...

Page 5: ...x Filters Greentime 1000 B E 1x Tap and attachments 1x Allen key 2 x Filters 9V Battery box Transformer b VERSIONS e VERSIONS OPTIONAL IP67 Battery Box IP67 Transformer Box 1x Tap and attachments wit...

Page 6: ...Preparation for Installation Flush water supply lines thoroughly before installing the faucet Do not allow dirt Teflon tape or metal particles to enter the faucet Shut off water supply Important All p...

Page 7: ...installed between the flexible pipe and the shut off valve not supplied Step 4 Connecting the power source 1 Connect the power source a For Green time B or Green Time 1000 B install the battery box a...

Page 8: ...ou are The following examples show how to manage the adjustment levels Example 1 You wish to adjust the flow time to 20 seconds At level 1 perform 3 steps of 1 second you will get 3 seconds Total 3 se...

Page 9: ...s performed 7 If your desired flow time is within 10 seconds no other adjusting levels are needed and you can stop pressing the Piezo cap The LED will blink 2 times then 3 times and after 4 times you...

Page 10: ...vel management system has activated step 1 and the user touches the designated area Step 2 At his point the battery might not have enough power to open and close the solenoid valve The battery level m...

Page 11: ...before you will operate the system Important Since water contacting the battery terminals rapidly drains the battery do not allow moisture or water into the system while the battery is being replaced...

Page 12: ...ing water 4 Reassemble the parts 5 Reconnect the flexible pipe and restore the incoming water supply 6 Make sure that there is no water leakage Care and cleaning of chrome and special finishes DO NOT...

Page 13: ...s See page 9 Check the flow time See page 6 Check the connection between the piezo cap connector and the solenoid connector Check that the battery box is correctly connected Check the solenoid valve I...

Page 14: ...06522042 06530020 06530021 Part Name Part code GREEN TIME GREEN TIME B GREEN TIME E Interoperable Solenoid Valve Seals and Screws Kit Cover Kit for Green Time 1000 Cover Kit for Green Time 1000 B E Mi...

Page 15: ...price of the faucet valve or control If you believe that you have a warranty claim contact your Stern Distributor Dealer or Plumbing Contractor Please be sure to provide all pertinent information rega...

Page 16: ...avne Israel Tel 972 8 9326000 Fax 972 8 9326025 export sternfaucets com www sternfaucets com 15 Gan Rave Blvd 81222 Gan Rave Yavne Israel Tel 972 8 9326000 Fax 972 8 9326025 export sternfaucets com ww...