Indicator Light 

Description 

FULL 

Light indicates when product water storage tank is full 

FLUSHING 

Light indicates the 60 second flushing cycle before every production cycle 

PRODUCING 

Light indicates the reverse osmosis unit is producing water 

LOW WATER 

Light indicates adequate feed water pressure 
NO Light indicates low feed water pressure 

POWER 

Light indicates unit is supplied with electrical power  

 

 

 

 

 

 

Sediment Filter 

GB2020 

Sediment Filter 

GB2005 

Carbon Filter 

CB2005 

Membrane 

TFM-100 (x3) 

Carbon Post Filter 

IC10T 

 

 

 

 

 

 

 

CONTROLLER 

REPLACEMENT FILTERS 

Summary of Contents for SRO-300

Page 1: ...1 SRO 300 INSTALLATION MANUAL 12630 US 33 N Churubusco IN 46723 Ph 260 693 1972 Fax 260 693 0602 www sterlingwatertreatment com ...

Page 2: ... hardness This unit is not supplied with a storage tank but may be used with either an atmospheric non pressurized or pressurized style tank If an atmospheric storage tank is used a float switch must be used to turn power off to the system 1 Disconnect tubing and remove end cap from membrane housings 2 Install membranes in housings The brine seal around the membrane must be on the inlet side of th...

Page 3: ...nlet valve will open and pump will start running Reverse osmosis unit will Auto Flush a high flow of water to the drain for 60 seconds The following lights should be illuminated on the control panel POWER LOW WATER PRODUCING FLUSHING 5 After the flushing cycle slowly close the PRESSURE REGULATOR adjustment knob turn clockwise on the drain line and monitor the concentrate and permeate water flow 6 ...

Page 4: ...le PRODUCING Light indicates the reverse osmosis unit is producing water LOW WATER Light indicates adequate feed water pressure NO Light indicates low feed water pressure POWER Light indicates unit is supplied with electrical power Sediment Filter GB2020 Sediment Filter GB2005 Carbon Filter CB2005 Membrane TFM 100 x3 Carbon Post Filter IC10T CONTROLLER REPLACEMENT FILTERS ...

Page 5: ...anty Not Cover This warranty does not cover the disposable sediment and carbon filters whose service life depends on feed water conditions In addition the membrane is only warranted if the required feed water conditions are met The above warranty will also not apply to any part of the R O Drinking Water System that is damaged because of neglect misuse alterations accident misapplication physical d...

Reviews: