Sterling OXY3 Series Installation Instructions And Owner'S Manual Download Page 11

10 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to unit specifications for quantity of media required. 

OXY10P

 media is recommeded when incoming water pH is 7.0 or greater and no manganese is 

present. 

IP10

 media is recommended when incoming water pH is less than 7.0 and no manganese is present. 

IP10M

 media is recommended when manganese is present in water supply.

 

 

 

Ref # 

Part Number 

Description 

CV3105 

O-Ring, -215 

CV3151 

Nut, 1” Quick Connect

 

OX-7 

Back Tube Adaptor (

OXY3-10, OXY3-15 & OXY3-20

OX-15 

Back Tube Adaptor (OXY3-30 & OXY3-40) 

CV3150 

Split Ring Retainer 

OXY3-10/15 Valve Assembly 

Complete Control Valve includes backtube assy 
(ref #9) and bypass valve (OXY3-10 and OXY3-
15) 

OXY3-20 Valve Assembly 

Complete Control Valve (includes backtube assy) 
for OXY3-20 

OXY3-30/40 Valve Assembly 

Complete Control Valve (includes backtube assy) 
for OXY3-30 and OXY3-40 

CD1400 

Distributor Head 

CD1220-01 

Distributor Head w/Fillport 

D100S-54 

Distributor Tube, 1” x 54” (OXY3

-10 & OXY3-15) 

D100S-48 

Distributor Tube, 1” x 48” (OXY3

-20) 

D100S-65 

Distributor Tube, 1” x 

65

” (OXY3

-30 & OXY3-40) 

MTP1054N 

Mineral Tank, 10” x 54” (OXY3

-10 & OXY3-15) 

MTP1248N 

Mineral Tank, 12” x 48” (OXY3

-20) 

MTP1465N 

Mineral Tank, 14” x 65” (OXY3

-30) 

MTP1665N 

Mineral Tank, 16” x 65” (OXY3

-40) 

6* 

OXY10P 

OXY Media Blend 

IP10 

Iron Pro Media Blend 

IP10M 

Iron Pro Media “M” Blend

 

QC20 

20 pounds ¼” x 1/8” gravel (OXY3

-10 & OXY3-15) 

QC25 

25 pounds ¼” x 1/8” gravel ( OXY3

-20) 

QC35 

35 pounds ¼” x 1/8” gravel ( OXY3

-30) 

QC50 

50 pounds ¼” x 1/8” gravel ( OXY3

-40) 

JG-38CV 

3/8” Check Valve

 

OX-7 Assembly 

Back Tube Assembly, includes 2 each o-rings (A), 
quick release nuts (B), and retainers (D) and 1 
back tube (C) (OXY3-10, OXY3-15 and OXY3-20) 

OX-15 Assembly 

Back Tube Assembly, includes 2 each o-rings (A), 
quick release nuts (B), and retainers (D) and 1 
back tube (C) (OXY3-30 and OXY3-40) 

Component Parts List 

Summary of Contents for OXY3 Series

Page 1: ...t 12630 US Highway 33 N Churubusco IN 46723 Phone 260 693 1972 Fax 260 693 0602 www sterlingwatertreatment com OXY3 Instruction Manual 112310 docx OXY3 Series Iron Reduction System Installation Instructions and Owner s Manual ...

Page 2: ...turally exists in some water sources in either clear water ferrous state red water ferric state or bacterial form The OXY3 iron filter can reduce any of these forms of iron Manganese A naturally occurring metallic element Manganese concentrations as low as 0 05 milligrams liter mg l can combine with oxygen to cause dark brown or black staining on fixtures Additionally manganese can cause an odor i...

Page 3: ...nsure optimum filter performance and satisfactory water quality The following factors should be considered in selecting the location of the iron filter 1 The filter should be installed after the pressure tank private well system only 2 The filter should be installed as close as possible preferably within 15 to an adequate floor or laundry drain capable of handling the backwash cycle volume and flo...

Page 4: ...s Do not reinstall the fillport cap until Step 9 STEP 4 Place filter tank on right side with inlet outlet facing left Place aeration tank on left with inlet outlet facing right STEP 5 Attach the control valve assembly to the front inlet opening of the aeration tank and outlet opening of the filter tank Attach the straight pipe adapter to the back outlet of the aeration tank and inlet of the filter...

Page 5: ...r less AVOID OVERHEAD DRAINS STEP 9 Use a garden hose or bucket to fill the media tank with water through the fillport Ensure media has been cleaned from fillport threads and install cap securely with wrench provided STEP 10 Be sure the control valve is in the Service position refer to timer operation for instructions The bypass valve should be in the Bypass position Open main supply valve or turn...

Page 6: ...he metal tabs outward on the desired days of regeneration The OXY3 Filter should be set to backwash a minimum of every third day Ensure the filter does not backwash for the first two days of operation to prevent media from being backwashed to the drain How to Manually Initiate a Backwash Cycle 1 Grab the manual regeneration knob and turn clockwise 2 The drive gear will engage the program wheel and...

Page 7: ... pins does not decrease air draw time 4 AIR DRAW cycle may be lengthened by increasing the number of holes between the two sets of pins Each hole represents 2 minutes of air draw time The air draw time should only be increased by moving the backwash pins to an earlier point on the program wheel Ensure that lengthening the air draw time does not decrease either the backwash or rapid rinse times 5 R...

Page 8: ...7 Control Valve Wiring ...

Page 9: ...pm Backwash 5 0 5 0 7 0 9 0 10 0 Air Draw and Slow Rinse 0 9 0 9 0 9 0 9 0 9 Rapid Rinse 5 0 5 0 7 0 9 0 10 0 FACTORY REGENERATION SETTINGS Backwash minutes 8 8 8 8 8 Air Draw Rinse minutes 14 14 14 14 14 Rapid Rinse minutes 8 8 8 8 8 Total Water Used gallons 93 93 125 157 173 DIMENSIONS in Mineral Tank diameter x height 10 x 54 10 x 54 12 x 48 14 x 65 16 x 65 Overall length x width x height 24x 1...

Page 10: ...9 Component Parts Breakdown A B C D 2 8 9 1 3 4 5 6 9 7 5 ...

Page 11: ...des backtube assy for OXY3 30 and OXY3 40 2 CD1400 Distributor Head 3 CD1220 01 Distributor Head w Fillport 4 D100S 54 Distributor Tube 1 x 54 OXY3 10 OXY3 15 D100S 48 Distributor Tube 1 x 48 OXY3 20 D100S 65 Distributor Tube 1 x 65 OXY3 30 OXY3 40 5 MTP1054N Mineral Tank 10 x 54 OXY3 10 OXY3 15 MTP1248N Mineral Tank 12 x 48 OXY3 20 MTP1465N Mineral Tank 14 x 65 OXY3 30 MTP1665N Mineral Tank 16 x ...

Page 12: ...11 Control Valve Breakdown ...

Page 13: ... H FV2510 1PH Powerhead Assembly 2510 TC 18 18303 Tank O Ring 2510 Valve I 60050 21 Drive Motor Assembly 19 13304 Distributor O Ring 121 J 60160 10 Drive Cam Assembly STF 20 13030 Distributor Retainer K 60304 13 Timer Assembly 3200 12 Day STF 120 60 21 40027 J tube for 2510 valve 1 14105 Bypass Valve Seal Single Lever 22 13911 Main Drive Gear 2 13305 Coupling O Ring 019 23 18743 1 Timer Motor 120v...

Page 14: ...13 ...

Page 15: ...14 ...

Page 16: ...r malfunction occur contact the dealer that you purchased the product from If you are unable to contact the dealer contact First Sales LLC 260 693 1972 We will require a full description of the problem model number date of purchase and selling dealer s business name and address We assume no warranty liability in connection with this water conditioner other than specified herein This warranty is in...